Remove/Replace Front Club Probe - Prince Castle DCFT-MCD Series Service Manual

Vertical toaster
Hide thumbs Also See for DCFT-MCD Series:
Table of Contents

Advertisement

Unplug Unit.
1
Failure to disconnect power
from the unit before servicing
could result in severe bodily
injury or death. The ON/OFF
Switch does not disconnect
incoming power to the unit.
Refer to Club Removal. Page: 26.
2
Use 5/16" nut driver to remove screw from platen.
3
Remove Bracket.
Remove front club platen probe.
4
Cut zip-ties and remove sleeving from probe.
5
Feed new probe through sleeving. Secure with zip-
6
ties.
527-504revF_EN

Remove/Replace Front Club Probe

WARNING
Apply AOS silicon to probe.
7
Place probe in platen. Secure with bracket and 5/16"
8
screw.
Feed unsecured end of probe through lower slot in
9
platen.
After feeding end of probe through platen, reconnect
10
any necessary wiring.
Refer to club installation. Page: 28.
11
Feed new probe through sleeving. Secure with zip-
12
ties.
41
Vertical Toaster
DCFT-MCD Series
Printed in USA 1/15 © 2015