Remove/Replace Right Side Main Probe - Prince Castle DCFT-MCD Series Service Manual

Vertical toaster
Hide thumbs Also See for DCFT-MCD Series:
Table of Contents

Advertisement

Vertical Toaster
DCFT-MCD Series
Unplug Unit.
1
Failure to disconnect power
from the unit before servicing
could result in severe bodily
injury or death. The ON/OFF
Switch does not disconnect
incoming power to the unit.
Remove right side panel
2
Use 5/16" nut driver tot remove (2) nuts holding probe
3
bracket.
Cut zip-tie.
4
Unplug probe connector from yellow harness wire.
5
Remove probe.
6
Printed in USA 1/15 © 2015

Remove/Replace Right Side Main Probe

WARNING
Apply AOS Silicone to new probe
7
Push probe into platen opening.
8
Position probe wires to run underneath bracket.
9
use 5/16" nut driver to install probe bracket.
10
Plug in probe to yellow harness wire.
11
Use one zip-tie to dress wiring.
12
Install right side door.
13
Plug in unit.
14
40
527-504revF_EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcft-mcdauDcft-mcdceDcft-mcdnaDcft-mcdnz