Reuse sleeve for the replacement probe. Use zip-tie to
9
secure.
Replace the probe. Apply AOS silicon to probe.
10
Using a 5/16" nut driver, secure the probe onto the
11
platen.
Replace 2 rear screws.
12
Replace rear club half. This includes the ring, (4) bolts,
13
and (2) screws.
527-504revF_EN
Remove/Replace Rear Club Probe (Cont..)
Refer to club re-installation. Page 28.
14