Control Panel AV‑HS60C1/AV‑HS60C2
Power supply
AC d 100 V to 240 V, 50 Hz/60 Hz
Power consumption
40 W
AV-HS60C2 supports redundant power supply.
indicates safety information.
Control terminal
<MAIN FRAME> terminal
<MENU PANEL> terminal
<DVI-D> terminal
<USB> terminal
Display selector switch
<COM1 (M)> terminal
<COM2 (RS-232)> terminal
<GPI I/O> terminal
ME number
Other
Ambient operating temperature
Humidity
Dimensions (W×H×D)
Mass
r For AV‑HS60C1E/AV‑HS60C2E
Inrush current, measured according to European standard EN55103-1, on initial switch-on: 3 A, after a supply interruption of 5 s: 25 A (Each mains
input)
Control Panel AV‑HS60C4
Power supply
AC d 100 V to 240 V, 50 Hz/60 Hz
Power consumption
40 W
Supports redundant power supply.
indicates safety information.
Chapter 11 Specifications — Specifications
Compatible with 100Base-TX and AUTO-MDIX (For Main Frame AV-HS60U1/AV-HS60U2 connection)
f Connection cable (supplied with AV-HS60C1/AV-HS60C2): LAN cable (CAT5E), straight cable, STP (Shielded Twisted
Pair), 10 m (32.8 ft)
f Connector: RJ-45
* When connected to the <LAN> terminal, no video will be displayed on the Menu Panel AV-HS60C3.
Used only for the Menu Panel AV-HS60C3
f Connector: DVI-D
f Because an independent signal format is used, cannot be displayed on a DVI-D monitor.
f Cannot be used concurrently with a DVI-D monitor (computer) connected to the <DVI-D> terminal. Select with the
display selector switch.
Used for displaying menus to the DVI monitor (computer)
f Connector: DVI-D
f Monitor resolution: 1366×768 compatible monitor
f Cannot be used concurrently with the <MENU PANEL> terminal. Select with the display selector switch.
For DVI monitor (computer) menu operation
f Connector: USB (Type A, female)
f Cannot be used for the Menu Panel AV-HS60C3.
Switch for selecting <MENU PANEL> terminal or <DVI-D> terminal
RS-422 control terminal
For master connection for controlling external devices
f Connector: D-sub 9-pin (female), inch screw
RS-232 control terminal
For external device control connections
f Connector: D-sub 9-pin (male), inch screw
GPI IN: 8 inputs, general-purpose, photocoupler sensing
ALARM OUT: 1 output, open collector output (negative logic)
GPI OUT: 10 outputs, selected from general purpose, tally
Open collector output
f Connector: D-sub 25-pin (female), inch screw
f Logic is switchable by menu.
2ME
0 °C to 40 °C (32 °F to 104 °F)
10% to 90% (no condensation)
980 mm×153.4 mm×267 mm (38-19/32 inches×6-1/32 inches×10-1/2 inches) (excluding protrusions)
AV-HS60C1: Approx. 13.0 k] (28.6 lbs.) (excluding accessories)
AV-HS60C2: Approx. 13.9 k] (30.6 lbs.) (excluding accessories)