Maintenance settings

Software and hardware version

Version information
Information on the software and hardware versions of this unit can be displayed.
1
Select the <SYS> button → [MAINTENANCE] → [Status] tab.
2
Check the [System Version] display in the [System Version] column.
f Check the version of the overall system.
3
Check the display of the following columns.
[Main frame Soft1],
[Main frame Soft2],
[Main frame FPGA]
[Main Panel Soft],
[Main Panel FPGA],
[Main Panel CPLD]
[Sub Panel1 Soft],
[Sub Panel1 FPGA],
[Sub Panel1 CPLD]
[Sub Panel2 Soft],
[Sub Panel2 FPGA],
[Sub Panel2 CPLD]
Updates
Version of the software for the unit can be updated using a memory card.
For the latest software information and methods to upgrade the software version, refer to the following website.
http://pro-av.panasonic.net/ (English only)

Alarm

In this unit, the next alarm message will appear as a popup.
For error displays, the indicator part of [ALARM] in Menu Panel AV-HS60C3 is lit in red.
Alarm message
An alarm message is displayed in Menu Panel AV-HS60C3 when an alarm has occurred.
Alarm message
[ALARM! Fan Stop]
[ALARM! Power Failure]
[ALARM! Temperature]
Alarm status displays
The next hardware alarm can be checked from the <SYS> button → [MAINTENANCE] → [Alarm] tab page. This page can be displayed even if
[ALARM] of the Menu Panel AV-HS60C3 is selected.
1
Select the <SYS> button → [MAINTENANCE] → [Alarm] tab.
2
Check the display of each item in the [Main frame]/[Main Panel]/[Sub Panel1]/[Sub Panel2] column.
[Power A]
[Power B]
[Fan]
[Temperature]
r Display details
[No Alarm]
[Alarm]
[−]
Enabling/disabling the alarm display
1
Select the <SYS> button → [MAINTENANCE] → [Alarm] tab.
Chapter 8 System Menu — Maintenance settings
Check the versions of software and hardware of the Main Frame AV-HS60U1/AV-HS60U2.
Check the versions of software and hardware of the main control panel.
Check the versions of software and hardware of the sub control panel 1 (second Control Panel AV-HS60C1/AV-HS60C2/
AV-HS60C4).
Check the versions of software and hardware of the sub control panel 2 (third Control Panel AV-HS60C1/AV-HS60C2/
AV-HS60C4).
Type of trouble
Shutdown of the cooling fan
Power supply problem
Rise in the temperature inside the unit
Displays the status of problems in the cooling fan or power inside the power supply 1.
Displays the status of problems in the cooling fan or power inside the power supply 2.
Displays the problem status of the cooling fan. It is displayed in the [Main frame] column.
Displays the problem status of the internal temperature.
Shows that there are no problems.
Shows that there is a problem.
Not a target for determination.
f When a power supply unit is not mounted
f When [Off] is selected in each item of [Alarm Enable]
The alarm message disappears if [OK] is selected. Contact
your dealer immediately.