It is not possible to configure Call
Distribution: Outgoing for multi-
terminal access.

DECT

The LED of the RFP 21 is flashing, but
none of the cordless DECT tele-
phones is functioning.
The LED of the RFP 21 is continu-
ously lit up, but one of the cordless
DECT telephones is indicating "No
connection" .
Is it possible to increase the time for
the enrolment procedure?
Frequently Asked Questions
For further information, please refer to
the User Guide of your ISDN telephone.
You have configured multi-terminal ac-
cess and system access in parallel. All
outgoing calls are therefore established
via system access, and outgoing call dis-
tribution can be configured for system
access only (Configurator, Call Distribu-
tion: Outgoing menu).
A specific MSN can be seized for individ-
ual calls by means of a code-number
procedure. For further information,
please refer to the "OpenCom 100, Oper-
ation on standard Terminals" user guide.
Make sure the terminal setting for the
corresponding U
port has been set to
pn
RFP (Configurator, PBX Configuration:
Ports: U
menu).
pn
You have not configured a port for this
telephone. Configure a port in the Con-
figurator and start the enrolment proce-
dure (PBX Configuration: Ports: DECT-
PP menu).
You must manually enter the IPEI of the
cordless telephone in the Configurator.
The enrolment time is then increased to
one hour (PBX Configuration: Ports:
DECT-PP menu).