Opencom 120; Opencom 100; Authorisations - DETEWE OpenCom 100 Mounting And Commissioning

Hide thumbs Also See for OpenCom 100:
Table of Contents

Advertisement

OpenCom 120

The S
1 port is configured for
0
multi-terminal access, the S
port for system access.
The S
3 to S
6 ports are config-
0
0
ured as internal S
the call numbers 20 to 23.
The 18 U
ports are configured
pn
for OpenPhone 63 system tele-
phones with the call numbers 30
to 47.
The four a/b ports are config-
ured for analogue devices with
the call numbers 10 to 13.

OpenCom 100

The OpenCom 100 is configured
for operation in Germany.
Analogue devices: The dialling
mode (pulse dialling or DTMF) is
automatically detected, post-di-
alling is by means of DTMF with
flash.
All connected cord-bound termi-
nals ring when there are incom-
ing external calls.
The system PIN, for example for
the maintenance of telephone
books on system telephones, is
"0000."
Factory Settings on Delivery
2
0
buses with
0

Authorisations

The use of functions by a terminal on
the OpenCom 100 is regulated by
means of authorisations. These au-
thorisations are configured for user
groups, to which the users with their
terminals are then assigned.
Two user groups are preset: "Admin-
istrators" and "Guests." "Administra-
tors" have access to all functions of
the OpenCom 100 and unrestricted
configuration rights. Users in the
"Guests" group cannot configure the
OpenCom 100, are not permitted to
make external calls, and have only
restricted use of the terminal func-
tions of the OpenCom 100.
Note: When the OpenCom 100 is
commissioned, all connected devices
are at first in the "Administrators"
group until an Administrator pass-
word is entered. Subsequently, all de-
vices are automatically in the
"Guests" group (see also the chapter
Configuring the OpenCom 100 start-
ing on page 31). For more details on
the configuration of user groups,
please refer to the online help in the
chapter "User Manager."
The following terminal functions are
factory preset to the "Administra-
tors" group:
Telephony Functions
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OpenCom 100 and is the answer not in the manual?

Questions and answers

Table of Contents