Technical Specifications
Mains power supply
Rated power
Safety class
2 x Euro ISDN external
(OpenCom 110)
1 x Euro ISDN internal
(OpenCom 110)
– Supply voltage
– Supply power
– Range
2 x Euro ISDN switchable
(OpenCom 105, OpenCom 110)
6x Euro ISDN switchable
(OpenCom 120 )
– Supply voltage
– Supply power
– Range
4 x U
(OpenCom 105)
pn
8 x U
(OpenCom 110)
pn
18 x U
pn
– Supply voltage
– Supply power
– Range
4 x a/b
– Supply voltage
– Supply power
72
(OpenCom 120)
230 V ~ 50 Hz
OpenCom 105:
OpenCom 110:
80 VA
80 VA
2
For basic access, DSS1 protocol
For ISDN devices, DSS1 protocol
40 V ± 10 %
3 W
150 m
For basic access, DSS1 protocol or for ISDN devices,
DSS1 protocol
For basic access, DSS1 protocol or for ISDN devices,
DSS1 protocol
40 V ± 10 %
3 W internal
150 m internal
For system terminals and RFPs
For system terminals and RFPs
For system terminals and RFPs
40 V ± 10 %
3 W per U
bus
pn
1,000 m
For analogue telephones with pulse or DTMF dial-
ling, flash duration 60 to 310 ms
40 V ± 10 %
25 mA
OpenCom 120:
130 VA