A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
The following table outlines the changes made to the manual during each revision. Page numbers refer to the
previous version.
Revision code
Date
1
July 1992
2
June 1993
2A
March 1994
3
February 1995
4
July 1996
5
May 1997
6
April 2000
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Revision History

Cat. No. W218-E1-6
Original production.
The manual was converted to an A4 layout and the following
corrections made.
Pages 19, 21: Note about external connectors added.
Page 41: SYSMAC LINK Unit model number corrected.
Page 54: Ohm symbol restored in first paragraph.
Pages 70, 72: Products added to standard-models tables.
Multipoint I/O changed to High-density I/O throughout the
manual. Scan time changed to cycle time throughout the
manual. C200H-BCjj1-V1 Backplane changed to C200H-
BCjj1-V1/V2 Backplane throughout the manual.
Pages 10, 27, 31, 32, 35: Corrections were made and
C200H-B7AO1 B7A Interface Unit added to the text.
Page 32: Reference corrected for SYSMAC NET Link Unit
and SYSMAC LINK Unit.
Page 38: Table updated.
Page 39: Notes corrected.
Group-2 B7A Interface Units were added beginning on page
139 and to the following pages: 11, 31, 32, 38, 40, 71, 80, and
140.
The name of previous the B7A Interface Unit was changed to
the Standard B7A Interface Unit and the C200H SYSMAC
LINK and SYSMAC NET Units globally replaced with C200HS
Units.
Page 47: Note added concerning AC input devices.
Pages 11, 19, 107: C200H-ID111 added.
Pages 10, 27, 31, 35, 40, 70, 107: C200H-OD21A added.
Pages 14, 18, 19, 27, 79, 149: E-shape Units added.
Pages 41, 70, 84: C200H-IA222V added.
Pages 41, 70, 92: C200H-OA222V added.
Pages 41, 70, 92: C200H-OA222 deleted.
Pages 41, 70, 94: C200H-OA122-E added.
Pages 41, 70, 93: C200H-OA223 added.
Pages 41, 94: C200H-OA224 added.
Page 42: C200H-DA002 added.
Pages 43, 44: SYSMAC LINK Units updated.
Page 64: Fuse specifications table added.
Pages 69 to 77: Standard models updated.
PRECAUTIONS section added.
Pages 17: Grounding symbol for DC Power Supply Unit
changed.
Pages 42, 72: C200H-CT021 added.
In addition to the inclusion of an index and this revision history, changes were made on the following
pages.
Page v: Minor changes to icons used for safety information.
Pages xii to xiv: Major changes to safety information.
Page 17: Minor changes to graphics.
Page 23: Information on Memory Units added.
Page 41: Information added to middle table.
Page 45: "Maximum" removed from middle paragraph.
Page 46: Information on DC two-wire sensor connection precautions added.
Page 79: Minor changes to measurement units.
Page 110: Information on alarm output, circuit configuration, and terminal connections added.
Page 115: Information on DC Input Units added.
Pages 116-118, 125-127, 136-138: Changes made to circuit configuration diagrams, and information on
manufacturing numbers and wiring output circuits added.
Page 145: Information on B7A Interface Units added.
Revision code
Revised content
Page 71: Notes about ordering added.
Page 93: Maximum switching capacity per Unit corrected.
Page 102: A and B in the Terminal Connections CN1 dia-
gram were switched.
Page 104: "m+1" and "m" in the Terminal Connections dia-
gram were switched.
Pages 40, 41: Models added and updated.
Pages 42, 43: Calculation examples text corrected.
Page 44: I/O Unit Cover description added.
Page 46: Bottom circuit diagram corrected.
Page 48: Ambient conditions added.
Pages 67 to 72 : Standard Models lists has been updated.
Page 90: "8 A/Unit" in Terminal Connections changed to "16
A/Unit."
Page 130: B7A Interface Unit specifications added.
Page 65: Step added to fuse replacement procedure and
illustration changed.
Page 66: Step added to relay replacement procedure and
illustration changed.
Page 76: Small correction for LSS. SSS models added.
Page 79: Insulation resistance and caution changed.
Page 142: Backplane Installation Plate dimension "W"
changed.
Page 79: Power consumption for C200H-CPU23-E, PS211
corrected.
Pages 89, 90: Operating input voltage corrected.
Page 94: Fuse voltage corrected for C200H-OA121-E cir-
cuit configuration.
Pages 117, 119, 120, 122, 124, 125, 127, 129, 131, 132:
Resistances removed from the circuit configuration.
Pages 123, 125: Max. switching capacity and rated input
voltage corrected for connectors 1 and 2.
Page 135: Notes corrected
Pages 138, 146, 147, 148: B7A and Group-2 B7A perfor-
mance specifications added to.
Pages 149 to 151: Dimensions corrected and added to.
Page 156: Backplane Insulating Plate dimensions modified.
Page 45: Tightening torque corrected for 4-4 I/O Connec-
tions.
Pages 45, 57, 58: Power supply wiring description added.
Page 79: Enclosure rating corrected.
Pages 103, 104: Circuit configuration changed.