Omron SYSMAC C200H Installation Manual page 95

Hide thumbs Also See for SYSMAC C200H:
Table of Contents

Advertisement

Specifications
AC Input Unit C200H-IA222/IA222V
Circuit Configuration
200 to
240 VAC
Terminal Connections
88
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Rated Input Voltage
Operating Input Voltage
Input Impedance
Input Current
ON Voltage
OFF Voltage
ON Response Time
OFF Response Time
No. of Circuits
Internal Current Consumption
Weight
Dimensions
IN
0.15 µF
680 Ω
IN
680 kΩ
910 Ω
COM
Input indicator
1
3
5
7
200 to
240 VAC
9
11
13
15
COM
200 to 240 VAC 50/60 Hz
170 to 264 VAC 50/60 Hz
21 kΩ (50 Hz), 18 kΩ (60 Hz)
10 mA typical (at 200 VAC)
120 VAC min.
40 VAC max.
35 ms max. (at 200 VAC, 25°C)
55 ms max. (at 200 VAC, 25°C)
1 (16 points/common)
10 mA 5 VDC max.
300 g max./400 g max. (IA222V)
B-shape
Internal
circuit
0
B0
A0
2
B1
A1
4
B2
A2
6
B3
A3
8
B4
A4
10
B5
A5
12
B6
A6
14
B7
A7
B8
NC
A8
B9
NC
Appendix B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpu21-eCpu23-eCpu31-e