2.6.6 Remote Status LED's

It is possible to connect remote Status LED's to the PPM3 programmer. This can be useful if the
programmer is mounted underneath a Test Fixture thus obscuring the normal Status LED's. The
Remote Status LED's simply connect to the 'Remote System Status' port (J13 Molex Connector) as
detailed in the table below.
Fig. 2.6.6 Remote System Status Connector and pin-out
Connector
Connector pin-out
See table below
Pin Signal name Description / Function
1
FAIL+
Connect to ANODE of FAIL LED
2
FAIL-
Connect to CATHODE of FAIL LED
3
BUSY+
Connect to ANODE of BUSY LED
4
BUSY-
Connect to CATHODE of BUSY LED
5
OK+
Connect to ANODE of OK LED
6
OK-
Connect to CATHODE of OK LED
The ANODE of each LED should be connected to the relevant '+' connector and the CATHODE of
each LED should be wired to the relevant '-' connector. It is not necessary to insert a series resistor
with each LED as these are already included on the PPM3 circuit board.