Equinox Systems PPM3 MK2 User Manual page 30

Production isp programmer
Table of Contents

Advertisement

3
Powering the programmer / Target System
3a
Select the required method of powering
the programmer
3b
Powering the programmer using an
external power supply adaptor
3c
Powering the programmer from the Target
System at +5.0V
3d
Programmer and Target System are
Independently powered
PPM3 MKII Programmer - User Guide - V1.04 - 10
The PPM3 programmer supports the following
power supply methods:
Programmer powered from external 9.0 –
12.0V DC regulated supply (eg. mains
adaptor) – see (3b)
Programmer is powered from the Target
System at +5.0V – see (3c)
Programmer and Target System are
independently powered – see (3d).
Plug power supply jack into mating jack
socket on the rear of the programmer.
External power supply must be 9.0 to
12.0V DC regulated
Plug the mains adaptor into the mains
supply but do not switch the power on.
The Target System supplies +5.0V to the
programmer via either the ISP Cable /
Header or the screw terminal power
connectors.
The mains power supply adaptor must
NOT be used if you are powering from
the Target System.
The programmer is powered from +9.0 to
12.0V via the DC power input on the rear
panel of the programmer.
The Target System is powered from an
independent power supply.
The Vcc connection between the
programmer and Target System must be
removed.
The programmer 'I/O Level Convertor'
must be powered at the same voltage as
the Target System. This can be set up in
the Programming Project,
th
May 2008
19