Equinox Systems PPM3 MK2 User Manual page 83

Production isp programmer
Table of Contents

Advertisement

Fig. 4.9.1 Settings - Programmer and Target System are independently powered
#
Paramater
Description
1
Programmer
Input voltage
source
2
V_Target
(Output voltage
to Target
System)
3
Vcc Option Link
4
LK1 Link
5
Programmer
I/O Level
Converters
72
External 9.0 – 12.0 V DC regulated supply via external power supply.
Connect power supply to either DC Jack Socket or 2-way Molex Power
Connector on the rear panel of the programmer.
Programmer must be set up to output the same voltage to the
programmer 'Line Driver Circuitry' as the Target Voltage.
This voltage is ONLY applied to the programmer 'Internal Line
Converter Circuitry', not to the Target System !
This ensures that the programmer I/O drivers are interfacing to the
same voltage levels as on the Target System.
The Voltage / current setting must be set up in the Programming
Project
Not Fitted
Not Fitted
Programmer Vcc signal should NOT be connected to the Target
Vcc
This may involve physically cutting the Vcc signal line in the ISP cable.
Programmer I/O Level Converter is powered at the Controlled Voltage
which is the same as the Target System voltage.
Eg. if the Target Voltage is 3.3V, then the Level Converter Voltage is
also 3.3V.
PPM3 MKII Programmer - User Guide - V1.04 - 10
th
May 2008

Advertisement