Instructions - Equinox Systems PPM3 MK2 User Manual

Production isp programmer
Table of Contents

Advertisement

4.7.2 Instructions

The instructions below detail how to set up the programmer to supply a controlled voltage to the
Target System.
1. Create a Programming Project which powers the Target System
In EQTools – Project Builder – Select the <Target Power Supply Settings> tab
Set the required 'Target Voltage' and 'Tolerance' eg. 3.3V +/- 500mV.
The Voltage 'Stabilise Time' should be set to a long enough time to allow the voltage to reach
its final voltage (default: 200ms).
Under the 'Programmer Controlled Power Supply' section,
select: <Programmer controlled Target Power Supply: ON>
This enables the programmer to supply power to the Target System.
Enter the maximum current which your Target System could take from the programmer supply
(worst case i.e. current inrush condition)
Leave all other settings as the default values
PPM3 MKII Programmer - User Guide - V1.04 - 10
th
May 2008
65