Fig. 3.3.2 Communications – DIP Switch Settings
Mode
Node
DIP Switch Setting
Address
RS-232
0
RS-485
0
RS-485
1
RS-485
2
RS-485
3
The layout of the DIP switch is shown in the diagram below.
PPM3 MKII Programmer - User Guide - V1.04 - 10
Comment
RS-232 Mode Enabled
(factory default)
Set DIP Switch 5 to the 'RS-232'
position
Programmer now uses the 9-way COM
port on the rear panel of the module.
Communications address is set by DIP
switches 1-4 as a binary weighted
address in the range 0 – 15.
Factory Default address is 0.
(i.e. DIP Switches 1-4 in the ON or '0'
position).
RS-485 Mode Enabled
Set DIP Switch 5 to the 'RS-232'
position
Programmer now uses either of the RS-
485 ports on the rear panel of the
module.
Communications address is set by DIP
switches 1-4 as a binary weighted
address in the range 0 – 15.