Leica Viva TS16 User Manual page 85

Hide thumbs Also See for Viva TS16:
Table of Contents

Advertisement

Reflectors
Electronic Guide Light
EGL
Technical Data
Type
Leica SD cards
Battery internal
Protection against water, dust and sand
Type
All instruments
Humidity
Type
All instruments
Type
Additive
Constant [mm]
Standard prism,
0.0
GPR1
Mini prism,
+17.5
GMP101
360° prism,
+23.1
GRZ4 / GRZ122
360° Mini prism,
+30.0
GRZ101
Reflector tape
+34.4
S, M, L
Reflectorless
+34.4
Machine Auto-
+28.1
mation power
prism, MPR122
For Machine Control purposes only!
There are no special prisms required for ATRplus or for PS.
Working range:
Position accuracy:
Operating temperature
[°C]
−40 to +80
−20 to +55
Protection
IP55 (IEC 60529)
Protection
Max 95% non condensing
The effects of condensation are to be effectively
counteracted by periodically drying out the instru-
ment.
ATRplus
yes
yes
yes
yes
yes
no
yes
5m to 150m (15ft to 500ft)
5cm at 100m (1.97" at 330ft)
Storage temperature
[°C]
−40 to +80
−40 to +70
PS
yes
yes
yes
not
recommended
no
no
yes
85