5.3
Description

Combined adjustment

procedure step-by-
step
58
prism. These small deviations ATRplus offsets, are calculated individually for
each measurement and corrected electronically. This means that the hori-
zontal and vertical angles are corrected twice: first by the determined ATRplus
errors for Hz and V, and then by the individual small deviations of the current
aiming.
IF the task is to
adjust a combination of
instrument errors
adjust the tilting axis
adjust the circular level
adjust the laser/optical plum-
met
adjust the tripod
Combined Adjustment

(l, t, i, c and ATRplus)

The combined adjustment procedure determines the following instrument
errors in one process:
Instrument
Description
error
l, t
Compensator longitudinal and transversal index errors
i
Vertical index error, related to the standing axis
c
Horizontal collimation error, also called line of sight error
ATRplus Hz
ATRplus zero point error for horizontal angle option
ATRplus V
ATRplus zero point error for vertical angle option
The following table explains the most common settings.
1.
Leica Captivate - Home: Settings\TS instrument\Check & adjust
2.
Check & Adjust
Select the option: Check & adjust the compensator, index error,
line of sight error & automatic target aiming
3.
Next
4.
Face I measurement
THEN
Refer to
5.3 Combined Adjustment (l, t, i, c
and
ATRplus).
Refer to
5.4 Tilting Axis Adjustment
Refer to
5.5 Adjusting the Circular Level of
the Instrument and
Tribrach.
Refer to
5.7 Inspecting the Laser Plummet
of the
Instrument.
Refer to
5.9 Servicing the
(a).
Tripod.
Check & Adjust

Hide quick links: