Laser Guide - Leica Viva TS16 User Manual

Hide thumbs Also See for Viva TS16:
Table of Contents

Advertisement

Labelling
1.6.10
General
20
Description
Beam divergance
CAUTION
Class 2 laser product
From a safety perspective, class 2 laser products are not inherently safe for
the eyes.
Precautions:
Avoid staring into the beam or viewing it through optical instruments.
Avoid pointing the beam at other people or at animals.
a
8681_002

Laser Guide

The Laser Guide built into the TS16 G instrument produces a visible red laser
beam which emerges from the front side of the telescope.
The laser product described in this section is classified as laser class 3R in
accordance with:
IEC 60825-1 (2014-05): "Safety of laser products"
Direct intrabeam viewing may be hazardous (low eye hazard level), in particu-
lar for deliberate ocular exposure. The beam may cause dazzle, flash-blindness
and after-images, particularly under low ambient light conditions. The risk of
injury for laser class 3R products is limited because of:
a)
unintentional exposure would rarely reflect worst case conditions of (e.g.)
beam alignment with the pupil, worst case accommodation,
inherent safety margin in the maximum permissible exposure to laser radi-
b)
ation (MPE)
natural aversion behaviour for exposure to bright light for the case of vis-
c)
ible radiation.
Description
Maximum radiant power
Wavelength
Beam divergence
a
Laser beam
b
b
Exit for laser beam
Value
<1.5 mrad
Value
R30
R1000
4.8 mW c.w.
658 nm
0.1 mrad
Safety Directions