Description

3.2 Design

Communication solutions
The transmitter supports MODBUS RTU communication via the optical IrDA interface at the
display, enabling the change of different transmitter settings using the SIMATIC PDM
software tool.
The transmitter provides two pulse outputs for volume pulses or alarm. Optionally, a
MODBUS RTU communication module (RS 485 or RS 232) can be installed to enable
communication directly between a PLC/RTU and the transmitter.
3.2
Design
The SITRANS FUS080 transmitter is designed with fiberglass reinforced polyamide
enclosure for remote or compact installation. The remote versions are available with up to 30
meter distance from flowmeter to transmitter. When ordering as a compact version in the
series FUS380 and FUE380 the transducer cables are pre-mounted at the sensor.
The transmitter is available in an IP67 (NEMA 4X/6) enclosure and is designed for use in the
flowmeters series:
● SONOKIT (1-path or 2-path)
● FUS380 (2-path)
● FUE380 (2-path)
3.3

Features

The following features are available:
● Battery or mains-powered
● Battery-powered with 3.6 V Lithium dual D-cell batteries
● Suitable for pipe diameters from DN 100 (4") up to DN 1200 (48") (SONOKIT 1-path) or
● IP67 (NEMA 4X/6) rated polyamid enclosure
16
SITRANS FUS080 transmitter
DN 200 (8") up to DN 1200 (48") (SONOKIT 2-path)
SITRANS FUS080 Display
SITRANS FUS080 transmitter
Operating Instructions, 07/2012, A5E03059912-02