Parameter
CYCLE_TYPE
CYCLE_SEL
MIN_CYCLE_T
MEMORY_SIZE
NV_CYCLE_T
FREE_SPACE
FREE_TIME
SHED_RCAS
SHED_ROUT
FAULT_STATE
SET_FSTATE
CLR_FSTATE
MAX_NOTIFY
LIM_NOTIFY
CONFIRM_ TIME
WRITE_LOCK
UPDATE_EVT
BLOCK_ALM
ALARM_SUM
ACK_OPTION
WRITE_PRI
Page 42
Foundation Fieldbus RMA803 Remote Indicator User's Guide
Identifies the block execution methods available for this resource. The
supported cycle types are: SCHEDULED, and
COMPLETION_OF_BLOCK_EXECUTION.
Used to select the block execution method for this resource.
Time duration of the shortest cycle interval of which the resource is capable.
Available configuration memory in the empty resource. It must be checked
before starting a download.
Minimum time interval specified by the manufacturer for writing copies of NV
parameters to non-volatile memory. Zero implies it is never automatically
copied. At the end of NV_CYCLE_T, only those parameters that have
changed need to be updated in NVRAM.
Percent of memory available for further configuration. Zero in preconfigured
resource.
Percent of the block processing time that is free to process additional
blocks.
Time duration at which to give up on computer writes to function block RCas
locations. Shed from RCas does not happen, if SHED_RCAS = 0.
Time duration at which to give up on computer writes to function block ROut
locations. Shed from Rout does not happen, if SHED_ROUT = 0.
Condition set by loss of communication to an output block, fault promoted to
an output block or a physical contact. When Fault State condition is set,
output function blocks perform their FSTATE actions.
Allows the Fault State condition to be manually initiated by selecting Set.
Writing a Clear to this parameter removes the device fault state if the field
condition, if any has cleared.
Maximum numbers of unconfirmed notify messages possible.
Maximum numbers of unconfirmed alert notify messages allowed.
The time the resource waits for confirmation of receipt of a report before
trying again. Retry does not happen when CONFIRM_TIME=0.
If set, no writes from anywhere are allowed, except to clear WRITE_LOCK.
Block inputs continues to be updated.
This alert is generated by any change to the static data.
The BLOCK_ALM is used for configuration, hardware, and connection
failure or system problems in the block. The cause of the alert is entered in
the subcode field. The first alert to become active sets the Active status in
the Status attribute. When the Unreported status is cleared by the alert
reporting task, another block alert is reported without clearing the Active
status, if the subcode has changed.
The current alert status, unacknowledged states, unreported states, and
disabled states of the alarms associated with the function block.
Selection of whether alarms associated with the block is automatically
acknowledged.
Priority of the alarm generated by clearing the write lock.