5.12 Configuring the Remote Indicator using Field Device
Manager (FDM) system
The Remote Indicator can be configured through Field Device Manager, by using DTM/DD for
R440 release and by using DTM for R430 and R410 release. For more information, refer the FDM
manual #EP-FDM-11430, #EP-FDM-11410.
Revision 4
Foundation Fieldbus RMA803 Remote Indicator User's Guide
The delay time(in seconds) the MAO function block takes to set the fault
state status if an input becomes Bad and stays in that state fault state.
A value transferred as input 1 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 2 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 3 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 4 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 5 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 6 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 7 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
A value transferred as input 8 to LCD Transducer Block during fault
state condition. Transition will occur if MO_OPT bit is enabled.
List of inputs that have transitioned to fault state status.
Indicates event information when an event update (a change in set
values) occurs.
Indicates alarm information when a block alarm occurs.
The block supports the following modes:
AUTO (Automatic)
LO
O/S.
Standard block alarm will be supported.
The status values described in the Parameter Formal Model of Part
1 apply.