Adaptec 2025ZCR Installation Manual page 100

Adaptec 2025zcr raid controllers: install guide
Hide thumbs Also See for 2025ZCR:
Table of Contents

Advertisement

Adaptec RAID Installation Guide
The Adaptec controller BIOS reports a drive as a disk instead of a drive.
This condition can occur if SMOR is used to disable Boot Enable. If
you require access to disk drives connected to the Adaptec controller
during the boot process, set Bootable Devices to Normal.
After updating the Adaptec controller firmware or BIOS and restarting, LEDs 1 and 5
or 2 and 5 flash once per second.
These patterns indicate that the controller startup code detected a
firmware checksum error or a flash error. Disable the firmware,
BIOS, and SMOR and then replace them using the flash Mode 0
procedure. For details, refer to
A firmware upgrade is unsuccessful, causing the controller to hang the system.
You can temporarily disable the firmware, BIOS, and SMOR and
then replace them using the flash Mode 0 procedure. For details,
refer to
Appendix
After an upgrade of the controller BIOS only, pressing Ctrl+A at the system prompt
displays the message
Card not configurable.
Upgrade SMOR using the flash Mode 0 procedure. For details, refer
to
Appendix
D.
The floppy disk drive cannot be accessed after installing an Adaptec controller.
Use SMOR to enable the EBDA Relocation option. For details, refer
to
Using SMOR on page
C-4
Appendix
D.
2-11.
D.

Advertisement

Table of Contents
loading

Table of Contents