Summary of Contents for Adaptec 2231700-R - 5M Int Mini-sas X4 SFF-8087

  • Page 1 Adaptec Solutions Guide...
  • Page 3: Table Of Contents

    Backplane 826TQ..........11 UPERMICRO Adaptec RAID 31605 S Backplane 836TQ..........17 UPERMICRO Adaptec RAID 31205 Intel Backplane 5400 SEP ..........25 Adaptec RAID 3405 Intel Backplane 5400 Expander ........... 29 Adaptec RAID 3405 S Backplane 733TQ ..........33 UPERMICRO Adaptec RAID 3405 S Backplane 810TQ ..........
  • Page 5: Backplane 743Tq

    Adaptec RAID 3805 Backplane 743TQ UPERMICRO Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband...
  • Page 6 Order Number: 2247000-R Adaptec Solutions Guide Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3805 743TQ Connector Connector 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband JP51 2247000-R #2 CON1 - 0 CON1 - 1...
  • Page 7 Adaptec RAID 3805 with SMC 743TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings...
  • Page 8 Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 (1) = JP34 Backplane Type 2 (2) = JP37 Controller Type 1 (1) = JP33 Controller Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 = JP38...
  • Page 9 Adaptec RAID 3805 with SMC 743TQ Backplane SGPIO Jumper Placement Backplane Type 1 (1) = JP34 Backplane Type 2 (2) = JP37 Controller Type 1 (1) = JP33 Controller Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 =...
  • Page 11: Adaptec Raid 3405 Supermicro

    Adaptec RAID 3405 Backplane 815TQ UPERMICRO Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3405 Connector 815TQ Connector 2247000-R #1 CON0 - 0 CON0 - 1...
  • Page 12 Adaptec Solutions Guide CON0 - 3 CON0 - Sideband JP51 SEP Vendor...
  • Page 13 Adaptec RAID 3405 with SMC 815TQ Backplane AMI 9071 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings I2C Jumper Placement Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 =...
  • Page 14 (1) = JP34 Adaptec Solutions Guide Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 SDout #1 = JP40 Backplane Type 2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 15: Backplane 826Tq

    Adaptec RAID 31205 Backplane 826TQ UPERMICRO Firmware Version b12380 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 31205 Connector 826TQ Connector...
  • Page 16 Adaptec Solutions Guide 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband JP66 2247000-R #2 CON1 - 4 CON1 - 5 CON1 - 6 CON1 - 7 CON1 - Sideband JP68 2247000-R #3...
  • Page 17 Adaptec RAID 31205 with SMC 826TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper...
  • Page 18 Settings Adaptec Solutions Guide Jumper Placement Backplane Type 1 (1) = JP85 Backplane Type 2 (2) = JP102 Backplane Type 3 (3) = JP91 Controller Type 1 (1) = JP84 Controller Type 2 (2) = JP101 Controller Type 3 (3) = JP90...
  • Page 19 Adaptec RAID 31205 with SMC 826TQ Backplane ID_SDin#1 = JP65 ID_SDin#2 = JP67 ID_SDin#3 = JP74 Jumper Settings SGPIO Jumper Placement Backplane Type 1 (1) = JP85 Backplane Type 2 (2) = JP102 Backplane Type 3 (3) = JP91 Controller Type 1...
  • Page 20 I2C Reset #1 = JP83 I2C Reset #2 = JP86 I2C Reset #3 = JP89 SDout #1 = JP87 SDout #2 = JP88 SDout #3 = JP93 ID_SDin#1 = JP65 ID_SDin#2 = JP67 ID_SDin#3 = JP74 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 21: Backplane 836Tq

    Adaptec RAID 31605 Backplane 836TQ UPERMICRO Firmware Version b12380 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 31605 Connector 836TQ Connector...
  • Page 22 Adaptec Solutions Guide 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband JP66 2247000-R #2 CON1 - 4 CON1 - 5 CON1 - 6 CON1 - 7 CON1 - Sideband JP68 2247000-R #3...
  • Page 23 Adaptec RAID 31605 with SMC 836TQ Backplane CON3 - 15 CON3 - sideband SEP Vendor...
  • Page 24 Adaptec Solutions Guide AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings Jumper Placement Backplane Type 1 (1) = JP85 Backplane Type 2 (2) = JP102 Backplane Type 3 (3) = JP91 Backplane Type 4 (4)
  • Page 25 = JP90 Adaptec RAID 31605 with SMC 836TQ Backplane Controller Type 4 (4) = JP103 I2C Reset #1 = JP83 I2C Reset #2 = JP86 I2C Reset #3 = JP89 I2C Reset #4 = JP92 SDout #1 = JP87 SDout #2 =...
  • Page 26 Adaptec Solutions Guide Jumper Settings SGPIO Jumper Placement Backplane Type 1 (1) = JP85 Backplane Type 2 (2) = JP102 Backplane Type 3 (3) = JP91 Backplane Type 4 (4) = JP104...
  • Page 27 Adaptec RAID 31605 with SMC 836TQ Backplane Controller Type 1 (1) = JP84 Controller Type 2 (2) = JP101 Controller Type 3 (3) = JP90 Controller Type 4 (4) = JP103 I2C Reset #1 = JP83 I2C Reset #2 = JP86...
  • Page 28 = JP65 Adaptec Solutions Guide ID_SDin#2 = JP67 ID_SDin#3 = JP74 ID_SDin#4 = JP76 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 29: Adaptec Raid 31205 Supermicro

    Adaptec RAID 31205 Intel Backplane 5400 SEP Firmware Version b12380 or higher...
  • Page 30 Adaptec Solutions Guide Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2236600-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 31205 Axx6DRV3G Connector 2236600-R #1 CON0 - 0 HDD - 0 CON0 - 1 HDD - 1 CON0 - 2...
  • Page 31 Adaptec RAID 31205 with Intel 5400 SEP Vendor Vitesse VSC410 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 33: Adaptec Raid 3405 Intel Backplane 5400 Expander

    Adaptec RAID 3405 Intel Backplane 5400 Expander Note: Must have firmware version 2.06 or higher.
  • Page 34 Adaptec Solutions Guide Firmware Version b12415 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2236600-R Model: ACK-I-mSASx4-4SATAx1-0.5M R Description Adaptec 3805 Connector Intel 5400 Connector 2236600-R #1 CON0 - 0 SAS - 0 CON0 - 1...
  • Page 35 Adaptec RAID 3405 with Intel 5400 w/Expander SEP Vendor Vitesse VSC410 Enclosure Management is inband, no sideband required. Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 37: Adaptec Raid 3405 Supermicro

    Adaptec RAID 3405 Backplane 733TQ UPERMICRO Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with...
  • Page 38 Sideband Adaptec Solutions Guide Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3405 Connector 733TQ Connector 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband JP51...
  • Page 39 Adaptec RAID 3405 with SMC 733TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings...
  • Page 40: Type

    Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 SDout #1 = JP40 Backplane Type 2 (2) = JP42 Jumper Settings SGPIO Jumper Placement Backplane Type 1...
  • Page 41: Backplane

    Adaptec RAID 3405 with SMC 733TQ Backplane SDout #1 = JP40 Backplane Type 2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 43: Adaptec Raid 3405 Supermicro

    Adaptec RAID 3405 Backplane 810TQ UPERMICRO Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R...
  • Page 44 Adaptec Solutions Guide Description Adaptec 3405 Connector 810TQ Connector 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - not used CON0 - not used CON0 - Sideband JP51...
  • Page 45 Adaptec RAID 3405 with SMC 810 TQ Backplane SEP Vendor AMI MG9071 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings...
  • Page 46 Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 SDout #1 = JP40 Backplane Type 2 (2) = JP42 Jumper Settings SGPIO Jumper Placement Backplane Type 1...
  • Page 47 Adaptec RAID 3405 with SMC 810 TQ Backplane SDout #1 = JP40 Backplane Type 2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 49: Backplane 813Tq

    Adaptec RAID 3405 Backplane 813TQ UPERMICRO Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with...
  • Page 50 Sideband Adaptec Solutions Guide Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3405 Connector 813TQ Connector 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband JP51...
  • Page 51 Adaptec RAID 3405 with SMC 813TQ Backplane SEP Vendor AMI MG9071 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings...
  • Page 52 Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 SDout #1 = JP40 Backplane Type 2 (2) = JP42 Jumper Settings SGPIO Jumper Placement Backplane Type 1...
  • Page 53 Adaptec RAID 3405 with SMC 813TQ Backplane SDout #1 = JP40 Backplane Type 2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 55: Backplane 814

    Adaptec RAID 3405 Backplane 814 UPERMICRO Firmware Version b12379 or higher Cable Requirements: Data cable internal mini Serial Attached SCSI x4...
  • Page 56 (SFF-8087) to x4 (SFF-8484) Serial Attached SCSI Adaptec Solutions Guide Order Number: 2231700-R Model: ACK-I-mSASx4-SASx4-0.5M R Description Adaptec 3405 814 Connector Connector 2231700-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband...
  • Page 57 Adaptec RAID 3405 with SMC 814 Backplane...
  • Page 58 Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 59: Backplane 816A

    Adaptec RAID 3405 Backplane 816A UPERMICRO Firmware Version b12379 or higher...
  • Page 60 Adaptec Solutions Guide Cable Requirements: Data cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI Order Number: 2246800-R Model: ACK-I-mSASx4-mSASx4-0.5m R Description Adaptec 3405 Connector 816A Connector 2246800-R #1 CON0 - 0...
  • Page 61 Adaptec RAID 3405 with SMC 816A Backplane SEP Vendor AMI MG9071...
  • Page 62 Adaptec Solutions Guide Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings I2C Jumper Placement Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 SDout #1 = JP40 Backplane Type 2...
  • Page 63 (1) = JP33 Adaptec RAID 3405 with SMC 816A Backplane I2C Reset #1 = JP50 SDout #1 = JP40 Backplane Type 2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 65: Backplane 836El1

    Adaptec RAID 3405 Backplane 836EL1 UPERMICRO Firmware Version b12379 or higher...
  • Page 66 Adaptec Solutions Guide Cable Requirements: Data cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI, No sideband Order Number: 2257900-R Model: ACK-I-mSASx4-mSASx4-NoSB-0.5M Description Adaptec 3405 Connector 836EL Connector 2257900-R #1 CON0 - 0...
  • Page 67 Adaptec RAID 3405 with SMC 836EL Backplane Expander Vendor LSISASx28 - Must have boot record version 1.2 or higher OR MFG date of 5/5/07 or higher.
  • Page 68 Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 69: Backplane 933El1

    Adaptec RAID 3405 Backplane 933EL1 UPERMICRO Firmware Version b12379 or higher...
  • Page 70 Adaptec Solutions Guide Cable Requirements: Data cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI No Sideband Order Number: 2257900-R Model: ACK-I-mSASx4-mSASx4-NoSB-0.5M Description Adaptec 3405 Connector 933EL Connector 2257900-R #1 CON0 - 0...
  • Page 71 Adaptec RAID 3405 with SMC 933E1 Backplane Expander Vendor LSISASx28 - Must have boot record label "Boot:1.0" or higher OR MFG date of 5/5/07 or higher.
  • Page 72 Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 73: Adaptec Raid 3805 Intel Backplane 5400 Sep

    Adaptec RAID 3805 Intel Backplane 5400 SEP Firmware Version b12415 or higher...
  • Page 74 Adaptec Solutions Guide Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2236600-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5m R Description Adaptec 3805 Connector Intel 5400 Connector 2236600-R #1 CON0 - 0 SAS - 0 CON0 - 1 SAS - 1...
  • Page 75 Adaptec RAID 3805 with Intel 5400 w/Expander SEP Vendor Vitesse VSC410 Copyright 2007 Adaptec, Inc. All rights reserved.
  • Page 77: Adaptec Raid 3805 Supermicro Backplane 823Tq

    Adaptec RAID 3805 Supermicro Backplane 823TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with...
  • Page 78 Sideband Adaptec Solutions Guide Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3805 Connector 823TQ Connector 2247000-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband JP51 2247000-R #2 CON1 - 0 CON1 - 1...
  • Page 79 Adaptec RAID 3805 with SMC 823TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings...
  • Page 80 Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 (1) = JP34 Backplane Type 2 (2) = JP37 Controller Type 1 (1) = JP33 Controller Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 = JP38...
  • Page 81 Adaptec RAID 3805 with SMC 823TQ Backplane SGPIO Jumper Placement Backplane Type 1 (1) = JP34 Backplane Type 2 (2) = JP37 Controller Type 1 (1) = JP33 Controller Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 =...
  • Page 83: Adaptec Raid 3805 With Smc 825Tq Backplane

    Adaptec RAID 3805 with SMC 825TQ Backplane Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3805 Connector 825TQ Connector 2247000-R #1 CON0 - 0 CON0 - 1...
  • Page 84 Adaptec Solutions Guide CON0 - 2 CON0 - 3 CON0 - Sideband JP51 2247000-R #2 CON1 - 0 CON1 - 1 CON1 - 2 CON1 - 3 CON1 - Sideband...
  • Page 85 Adaptec RAID 3805 with SMC 825TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings...
  • Page 86: Controller Type

    Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 (1) = JP34 Backplane Type 2 (2) = JP37 Controller Type 1 (1) = JP33 Controller Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 = JP38...
  • Page 87 Adaptec RAID 3805 with SMC 825TQ Backplane SGPIO Jumper Placement Backplane Type 1 (1) = JP34 Backplane Type 2 (2) = JP37 Controller Type 1 (1) = JP33 Controller Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 =...
  • Page 89: Backplane 933El2

    Adaptec RAID 3805 Backplane 933EL2 UPERMICRO Firmware Version Under Development...
  • Page 90 Adaptec Solutions Guide Cable Requirements: Data cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI, No sideband Order Number: 2257900-R Model: ACK-I-mSASx4-mSASx4-NoSB-0.5M Description Adaptec 3805 Connector 933E2 Connector 2257900-R #1 CON0 - 0 CON1 - 1...
  • Page 91 Adaptec RAID 3805 with SMC 933E2 Backplane Expander Vendor LSISASx28 - Must have boot record label "Boot:1.0" or higher OR MFG date of 5/5/07 or higher.
  • Page 92 Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved.

Table of Contents