This manual contains installation instructions for installing the LNG Series dispenser. Included are mechanical,
transporting, wiring, and start-up instructions. For any additional installation information on ground storage modules,
shear valves, hoses, breakaways, and the Liquid Natural Gas System. Please refer to the manufacturer's installation
instructions for proper installation.

Related Documents

Bennett 515 Pump Controller Installation & Service Manual ---------------------------------------------- Part# 105022
Bennett 621 Interconnection Box Installation, Service, & Parts Manual ---------------------------------- Part# 116186
Bennett Natural Gas Series Operators Manual ------------------------------------------------------------- Part# 123919
Bennett LNG Series Service Manual ------------------------------------------------------------------------ Part# 120149
LNG Series Audit Report ----------------------------------------------------------------------------------- Part# 119640
Simply Secure Payment PCI 3.1 (SSP Color) Programming, Service, and Part Manual ------------------- Part# 124184
Simply Secure Payment PCI 3.1 (SSP Large Display) Programming, Service, and Parts Manual --------- Part# 128203

Power Requirements

AC Power Input, Electronic ............................................................................................................................ 120 VAC, 60 Hz. 560 Watts Max.
DC Power Supply Output ............................................................................................................................................ +5 VDC at 5.0 Amps Max.
Lead-Acid Battery Output ........................................................................................................................................... +12 VDC at 2.0 Amp Max.
Nickel-Cadmium Battery Output ...................................................................................................................... +3.6 VDC at 40 Milliamp Max.

Environmental Requirements

Operating Temperature Range .................................................................................................................. -20°C to +40°C (-4°F to +140°F)
Humidity ................................................................................................................................................................................. 0-95% non-condensing

Dimensions

LNG Series Maximum without valance ....................................................................... 54.25" (width) x 22" (depth) x 91.375" (height)
LNG Series Base .................................................................................................................................................... 43 ½" (width) x 19 ¼" (depth)

Codes and Standards

NFPA 30 – Flammable and Combustible Liquids Standard
NFPA 30A – Motor Fuel Dispensing Facilities Standard
NFPA 52 – Vehicular Gaseous Fuel Systems Code
NFPA 57 – Liquefied Natural Gas (LNG) Vehicular Fuel Systems Code
NFPA 59A – Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG)
NFPA 70 – National Electric Code
ASME/ANSI B31.3 – Process Piping
International Fire Code

Introduction

1
Introduction
+12 VDC at 1.75 Amps Max.
+24 VDC at 2.75 Amps Max.