Preventative maintenance

Introduction
To keep the unit into specifications, preventive maintenance has to be carried out, with
specific intervals to avoid breakdown, inefficient operation and to maximize the expected
lifetime, of 10 years or more.
It is important to notice, that intervals between filter maintenance can vary depending on the
specific environment. Moving parts are wearing parts, that needs replacements when worn
down, dependent on the specific environment.
The factory warranty is only valid if documented preventive maintenance has been carried
out. The documentation could be in form of a written log.
The following parts needs preventive maintenance:
Scope of
maintenance
Service interval
6 month
1 year
2 years
Replace filters
Check or replace filters when the filter alarm sounds, and flashes on the remote control. Al-
(1 year)
ways reset the filter timer after a filter replacement. See the remote control manual for more
information.
Filter intervals can be adjusted to adapt pollution level in the house, and outdoor air particle
content. See how in "User interaction" on page 22
Filters must, however, be checked every six months. Dantherm always recommends replac-
ing filters at least once a year. When checking the filters, clean the unit externally around the
filter openings with a damp cloth, to maintain good hygiene.
The filters are located behind the small lids, on the front panel

Service Guide

Task
Filter check. Change if required
Filter replacement
External condensate discharge
Heat exchanger
Fans
Drip tray/internal discharge
Internal air ducts
Fig. 25
To be carried out by:
User
User
Trained engineer
Trained engineer
Trained engineer
Trained engineer
Trained engineer