Initial calibration, continued
Calibration ,continued
20
Linksversion(A)
Left unit
unità sinistra
Continued from previous page
No
Action
Move the ΔPa meter across the
extract air path as shown. This
5
example is based on the unit being
in operation mode A.
Adjust the extract fan speed, according the guide in the PC-tool on your computer .
The goal is to adjust the fan until the ΔPa meter shows the pressure drop value that was
6
read in point no 2, deducted a few percent, in order to create a small under pressure
inside the house.
Disconnect the ΔPa meter, as well as the computer. The unit is now ready for many
7
years operation.