Components description

Introduction
This section describes the individual components of the HCC2 Alu. Please use the illustration
on page 3 for reference.
Cabinet outer parts are made of aluzink coated sheet metal, finished with powder paint. The
Cabinet
inner part is one moulded polystyrene block. If adding accessory or exchanging parts, access
to all parts are available, just by removing the front cover and drip tray.
The cabinet is internal sound and heat insulated, with fire retardant polystyrene foam. The
unit´s cabinet is designed for mounting in 12°-40° C ambient temperature
The unit is standard equipped with two G4 class cassette filter. These filters protects the
Filters
heat exchanger, and improves the inside environment by remove dust and particles, in both
airflows. F7 class filter can be purchased. If F7 is used, this is always placed in the supply air,
removing even smaller particles. Correct placement of F7 filters according mode selection, is
shown at page 11
Heat exchanger
The counter flow Aluminum heat exchanger absorbs the heat energy from extract air and
moves this heat energy to the ingoing supply air, resulting in domestic ventilation with low
heat loss.
The supply fan supplies fresh outdoor air through the unit's heat exchanger to the ducts,
Fans
where it´s distributed to bedrooms, living rooms and possibly sauna or steam bath.
The extract air fan draws used, moistened and polluted air from house, through the unit
and heat exchanger, in which the heat is absorbed and moved to supply air. Finally the air is
exhausted to the outside.
The unit are equipped with 2 pcs. spigot connections for draining condensed water. It is
Water drainage
mandatory to fit the spigot next to the T4 with a hose, discharging the condensed water to a
sever. Correct drainage is shown on the connection label placed on the unit. The remaining
un-used spigot is to be blocked with the enclosed cap.
Controller
The unit´s main controller is placed at the main PCB, together with I/O connections for inter-
nal as well as external connections. This illustrates the overall system architecture
HCC unit
USB service port
Fan 1 and Fan 2
HCC main
Internal RH% sensor
controller
Internal VOC sensor
Bypass damper
(accessory)
External parts
Proprietary wireless
remote
Ethernet router with
DHCP
ModBus out
for HAC only
Digital in
External pre-heater
Fig. 4
BMS systems
(e.g. KNX)
5