Operating Point Name
Detail: String fields allowing the operator to enter text names for each operating point.
Process Variables
Detail: Array of drop-down selection controls for selecting the
operating point. The available parameters for selection are analog inputs, battery voltage, digital input
parameters, cam phase, engine speed, and user variables. Typically, all operating points would utilize the
same process variable. For example, a set of four operating points could be created for four different ranges
of digital input frequency. However, complex operating point tables may be created using multiple inputs.
Time/Trigger Wildcards
Units: msec
Detail: Array of time values for each operating point while in
point elapses, execution will proceed to the next sequential operating point.
Detail: Array of text-based specifications for each operating point while in
When a
Trigger Wildcard
behavior of the operating point function while no
are satisfied is determined by the settings of the
parameters. The syntax for
Parenthesis Bounded (Lower Value, Upper Value)
Detail:
Trigger Wildcard
Value
Example: (20,40)
Bracket Bounded [Lower Value, Upper Value]
Detail:
Trigger Wildcard
than or equal to Upper Value
Example: [20,40]
than or equal to 40.
Note: A
Trigger Wildcard
Example: [20, 40)
than 40.
Single Point Value
Detail:
Trigger Wildcard
recommended to use this type of
Wildcard should be used for Boolean
180 | ni.com | NI DIDS-2100 Series User Manual
specification is TRUE, the associated operating point will be executed. The
Trigger Wildcard
is satisfied if the
Trigger Wildcard
is satisfied if the
is satisfied if the
Trigger Wildcard
is satisfied if the
can combine the usage of parenthesis and brackets.
Trigger Wildcard
is satisfied if the
is satisfied if the
Trigger Wildcard
Process
Trigger Mode
Timer
Trigger Wildcard
Undefined Trigger Behavior
entries is as follows:
Process Variable
is greater than Lower Value and less than Upper
Process Variable
Process Variable
is greater than or equal to Lower Value and less
Process Variable
Process Variable
Process Variable
is exactly equal to the single point value. It is not
for continuously variable
Variables.
process variable for each
Mode. After the time for each operating
Trigger
Mode.
is satisfied or multiple
Trigger Wildcards
and
Multiple Trigger Behavior
is greater than 20 and less than 40.
is greater than or equal to 20 and less
is greater than or equal to 20 and less
Process
Variables. This type of