Detail: When ON, operating points are active according to the operating point table, and the table values
will override the parameter values specified elsewhere within the DI Driver System setup windows. When
OFF, the parameter values will remain set to the most recent values used from the operating point table. For
example, HVTarget for DI Driver Module 1 may be set to 50V via the
Setup window may implement a time-based table for incrementing HVTarget by 10V every 10 seconds, from
50V to 100V. At the end of the operating point cycle, HVTarget will be left at the last operating point of 100V.
If it is desired that HVTarget be set back to 50V, then an additional operating point should be added to the
end of the table to revert back to 50V.
Pause OP
Tip Strip: In
Timer Mode
Detail: When ON, pauses the table to remain at the current operating point. When OFF, operating point
operation resumes. This parameter is only applicable when
Reset OP
Tip Strip: In
Timer Mode
Detail: In
Timer
Trigger
Mode. This parameter is only applicable when
Manually Set OP
Tip Strip: Causes execution of Manual OP
Detail: When ON, sets the operating point to the point specified by the value to the left of the button. In
Mode, when set to OFF execution will resume at the current operating point. In
OFF execution will resume at the operating point determined by the
Number of OP
Tip Strip: Number of operating points to be considered for execution
Detail: Specifies the number of operating points to be considered by the operating point function. For
example, if
Number of OP
Operating points 3 and greater will not be considered.
Error OP
Tip Strip: Operating point executed during error state
176 | ni.com | NI DIDS-2100 Series User Manual
pause operating point execution
reset operating point execution to point 0
Mode, when ON, resets the operating point back to zero. This parameter is not applicable to
is set to 3, then operating points 0, 1, & 2 will be applicable to the function.
DI1 Setup
is ON.
Enable OP
is ON.
Enable OP
Process Variable Trigger
window. The Operating Point
Trigger
Mode, when set to
Wildcards.