6. When the restoration process is completed, press Exit button to close the Real-Time System Backup dialog.
7. After the image restoration process, the DI Driver System will be rebooted automatically. Wait for the USER1 and
USER FPGA LEDs to start blinking, indicating the DI Driver System application is running.
8. If calibration files were backed up in step 1, use an FTP client to restore any .cdl calibration files. The .cdl
calibration files on the system controller should be located at "C:\ni-rt\LabVIEW Data\". After restoring the calibration
file, reset the controller or cycle the power.
NI DIDS-2100 Series User Manual | © National Instruments | 39