Detail: Indicates that the current rise rate to the associated channel is indicative of a short circuit condition.
This is a critical fault and will shut down the associated channel.
PFI_OpenFaultOverride
Tip Strip: Determines whether open-circuit faults are indicated
Detail: When set to OVERRIDE, the open circuit faults will be ignored and will not be indicated.
OpenCircuitFaults
Tip Strip: Lowside channel open-circuit fault
Detail: An open circuit fault is detected when the current never reaches the requested current level specified
by the lowest current setpoint in Phase 1 or Phase 2 of the PFI 1-4 tab. This is not a critical fault. If an open
circuit fault is indicated, pulses will continue to be delivered to the channel as normal. The open circuit fault
indicator is updated at the end of each delivered command pulse.
PFI Output Config
Tip Strip: Opens PFI Output Mode configuration window
Detail: This button opens a
PFI channels. Each channel is normally configured to drive a PFI injector, but each can be configured as
either an active high or active low digital output.
76 | ni.com | NI DIDS-2100 Series User Manual
window
that allows users to change the mode of output operation for each of the