Table2D_Xb_InputSelector
Tip Strip: Assigns signal source to the 2D lookup table Y array
Detail: Drop-down selection control for selecting the input parameter for the Y values of the lookup table. The
available parameters for selection are analog inputs, battery voltage, digital input parameters, cam phase,
engine speed, and user variables.
Table2D_X_Description
Detail: Text field for entering a lookup table description.
Table2D_X_FlexControlParameters
Tip Strip: Selects destination of the 2D lookup table output
Detail: Array of Flex Control parameter selectors. Each selector maps the lookup table output to a Flex
Control Parameter. The selected parameter will be overwritten by the lookup table output. The Flex Control
Parameter can be selected one of two ways: by left unclicking and searching through the full list of Flex
Control Parameters, shown above, or by right unclicking and searching through a hierarchical list of menus
to find the particular Flex Control Parameter of interest, as shown in the
Direct Mapping