Fusing; Fusing Unit; Exit Sensor - Ricoh Aficio 1013 Service Manual

Hide thumbs Also See for Aficio 1013:
Table of Contents

Advertisement

3.5 FUSING

3.5.1 FUSING UNIT

!
CAUTION
The fusing unit can become very hot. Be sure that it has cooled down
sufficiently before handling it.
1. Turn off the main switch, and unplug the machine.
2. Copy tray (☛ 3.3.3)
3. Fusing unit [A] (! × 3, " × 3)
NOTE: When reinstalling the unit
replace the spacer [B] in the
correct position, and
remember to set the
grounding wire [C] into place.

3.5.2 EXIT SENSOR

1. Fusing unit (☛ 3.5.1)
2. Exit sensor [A] (" × 1)
SM
3-13
FUSING
[C]
[B]
[A]
B046R501.WMF
[A]
B046R508.WMF
B044/B045/B046

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aficio 120Aficio 1013fB044B045B046

Table of Contents