11. Remove the E-Ring from the top of the Idler Panel Shaft.
12. Open the Entrance Idler Panel from the front side.
13. Carefully remove the Shaft.
14. Grasp and remove the Exit Idler Panel.
Repairs/Adjustments
E-Ring
Shaft
15. To replace the Exit Idler Panel Weldment do the following procedures
to remove and install these components.
REP 2.12 Idler Roller Replacement
REP 2.25.2
Top, Middle, & Bottom Exit Sensor (S22, S23, S24)
Replacement
REP 2.28.4
Exit Idler Solenoid Replacement
REP 2.11 Panel Close Magnet Replacement
Installation Procedure
1. Place the Exit Idler Panel in position.
2. Insert the Shaft through the holes (2) at the left side of the Exit Idler
Panel.
3. Install the E-Rings (2) at the top and bottom of the Shaft.
4. Connect the Connectors for Solenoids SOL5, SOL6 & SOL7 to the
header.
5. Connect the Connectors for Sensors S22, S23, & S24.
6. Install the Ground strap.
7. Place the sensor cables into the Cable Clamps, and close the Clamps
8. Do REP 1.11 to install the Downstream Side Frame Cover.
9. Do GP 6.3 Dock the Punch to connect the Punch to the downstream
devices.
10. Close the Front Door.
11. Connect the Power Cord.
12. Power ON the entire printing system.