Mounting Options; Rack Shelf Mounting; Ud-Kit Mounting; Electrical Connections - Lightware DP-OPT-TX150 User Manual

Fiber optical multimedia extender
Table of Contents

Advertisement

 
3. Installation
3.1. Mounting Options

WARNING!
For the correct ventilation and to avoid overheating ensure enough free space around the
appliance and do not cover it.
INFO:

In order to get the necessary mounting accessory please contact sales@lightware.com.

INFO:
More details about the accessories and the mounting can be found in the Mounting Assembly Guide
(https://lightware.com/pub/media/lightware/filedownloader/file/Assembly-Guide/Mounting_AG.pdf).
3.1.1. Rack Shelf Mounting
The 1U high rack shelf provides mounting holes for fastening four DP-OPT_150 extenders and put them into
a standard rack cabinet (width of the Rack shelf is 448 mm – without the ears). Fix the device to the Rack
shelf as shown in the figure:
3.1.2. UD-kit Mounting
Mounting with UD-kit (Under desk)
Mounting with UD-kit Double (Under Desk Double)
DP-OPT-TX150, DP-OPT-RX150 – User's Manual
3.2. Electrical Connections
3.2.1. Fiber Optical Connector
The extenders are assembled with standard SC receptacles.
3.2.2. DP Input and Output Ports
DP-OPT-TX150 and DP-OPT-RX150 provides DisplayPort connectors with Dual-mode support.
When a passive adapter is connected to the receiver, the source device is forced to switch to
DVI/HDMI mode.
3.2.3. USB Connectors
Standard USB connectors are built in the extenders supporting different features, but the pinout
of the connectors are the same.
3.3. Security slot
A Kensington-compatible security slot can be found on the side of
the units for theft protection. (Security cable is not supplied with
the extenders.)
Applied firmware package: v1.1.13 | LDC software: v2.5.1b5
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-opt-rx150

Table of Contents