Configuration Tool Settings
3.3.5 Color and Sound Configuration
Custom colors and custom sounds for different event types are created in the configuration tool (Tools >Color and
Sound Configuration) that is launched from the workstation's main menu (Configure >Launch Configuration
Tool). Color and sound settings are saved when exiting the configuration tool and clicking Yes to the Save Changes
prompt. Refer to the Intelligent Fire Integrator Configuration Tool Installation & Operation Manual (P/N 53380) for
additional information.
3.3.6 Event Color Coding
NOTE: The Administrator can customize workstation default color choices if required by the
Authority Having Jurisdiction. Document any custom color schemes for future reference.
Each event within the Intelligent Fire Integrator system has a corresponding color. This color coding is used when
displaying the event on-screen, when viewing events in history manager, and various other applications throughout
the software.
Each off-normal event has a corresponding normal event. Every normal discrete event within the workstation is
displayed with the color gray when in Graphics mode.
The default event color scheme is set to comply with the requirements in CAN/ULC-S527, Standard for Control
Units and Accessories for Fire Alarm Systems. Off-normal events and their corresponding default colors are listed in
Table
3.1.
Default
Event Color
• Pre-Alarm
• Verifying for Fire Alarm
• Alert Condition
• Soft Anti-Passback Warning
• Point Inactive
• Fault Condition
• Temperature Alarm
• Zone Trouble
• Ground Fault
• AC Power Failure
• Trouble
• Loop Trouble
• Very Low Value
• Very High Value
Yellow
• High Value
• Low Value
• Cover Open
• Out of Paper
• Transmission Trouble
• Fuse Failure
• Short Circuit
• Open Circuit
• Position Alarm
• Video Signal Loss
• Unlock
• Program Entry
• Program Exit
• Offline
Gray
28
Table 3.1 Event Icon Color Coding
Off-Normal Event
IFI-WS Installation and Operation Manual – P/N LS10050-000JC-E:A 12/11/2014
Default
Off-Normal Event
Event Color
• Fire Alarm (Non Latching)
• Alarm
• Agent Release
• Tamper Switch Activated
• Agent Release Abort
• Door Ajar
• Forced Entry
Red
• Recent Alarm
• Panic Alarm
• Supervisory Alarm
• Extremely Low Value
• Extremely High Value
• Addressable Input On
• Restart
• Security Alarm
• Audibles Silenced
• Off Normal Condition
• Bad Address
• Device Disabled
• Addressable Output On
• Device Non-Monitoring
• Armed
• Disarmed
Blue
• Armed Away Mode
• Armed Stay Mode
• Armed Instant
• Armed Maximum
• Test Mode Activated
• Manual Disable
• Schedule Disable
• Manual Output On
• Schedule Output On
Configuration Tool