5-36 Other Features
NOTE
When air pressure is relieved using the shut-off
valve, the normal extending and retracting oper-
ation cycle is disabled, for that reason the slide-out
cannot be moved with the control pad.
PNEUMATIC CONTROL PANEL
NOTE
Refer to the slide-out decal for correct direction of
rotation (clockwise or counter clockwise).
4. To move the slide-out, use a cordless power
drill with a 3/8" hexagonal bit on the shaft
extension of the slide-out motor.
5. Rotate the slide- out motor shaft extension
with the power drill until the slide-out comes
to its opened position.
6. Once the slide-out is lined up to its opened
position, remove the tool from the motor.
SLIDE-OUT MOTOR MANUAL ACTIVATION
NOTE
The front slide-out motor is located inside the 2nd
baggage compartment while the rear slide- out
motor is accessible from inside the vehicle, under
the bed structure..
Slow down on the closing speed as the slide-out
approaches its extended position. As soon as the
"out limit" stoppers come in contact with their
bearing surface, stop immediately the power drill
rotating movement. Not doing so could overload
the drive mechanism and cause damage to the
reduction gearbox.
INFLATABLE SEAL PRESSURE GAGE
NOTE
The slide-out control system inhibits transmission
range selection to prevent the vehicle from moving
if the slide-out is not in its full "IN" position.

SLIDE-OUT TROUBLESHOOTING

Error Condition Or Missing Operation Condition
When an error condition or a missing operation
condition is present on a slide- out, the green
indicator light on the corresponding control pad starts
blinking upon releasing of the IN/OUT rocker switch.
Turning the ignition OFF and ON again, will stop the
blinking and reset the fault. If the error condition or a
missing operation condition is still present, the
blinking will start again the next time that the slide-
out is operated.
PA-1638 Owner's Manual X3-45 VIP
CAUTION
7. Finally, the inflatable seal can be re-inflated
by
turning the shut- off
counterclockwise. Check the pressure gage
on the inflatable seal regulator to see if the
pressure is increasing to around 15 psi.
Needle should point between the green
indicator pegs.