9-12 Technical Information
Expansion tank above radiator and remote
l
mounted.
System pressure 15 psi.
l
Radiator fans: pusher type, 6 high power 24
l
Volts electrical fans, 12 inches diameter.
Coolant: -Volvo engine: ELC (Extended life
l
coolant), color red, with No-SCA filter.
CAC fans: pusher type, 2 high power 24 Volts
l
electrical fans, 12 inches diameter.
Thermostat: 82 / 92 °C (180 / 198 °F) –
l
(cracking / fully open).
Full system capacity 22.5 US gal (85 l).
l
Coolant filter.
l

FUEL SYSTEM

Polyethylene 208 US gallons (787 liters) fuel tank
centrally located.
Anti-spill device.
l
Two safety filler caps providing filling access
l
on both sides of the vehicle.
Pressure relief valve.
l
Electric fuel gauge.
l
Low level signal at 26 US gallons (98.4 liters).
l
Primary filter 25 microns (standard).
l
Primary fuel filter with electrical water
l
indicator (Volvo D13).
Fuel Pro 382 filter available as an optional
l
primary filter.
Secondary filter 3 to 5 microns.
l
Shut-off valve on fuel supply line.
l

EXHAUST SYSTEM

One all stainless steel exhaust & aftertreatment
system including:
Catalylic converter to reduce NOx.
l
Aftertreatment system made of a DPF
l
(Diesel Particulate Filter), DOC (Diesel
Oxidation Catalyst) and SCR system. Noise,
vibration and heat insulated. This ATD is
mounted to the vehicle structure and is
accessible through an exterior access door.
Tail pipe diffuser and rain deviation device.
l

HEATING AND AIR CONDITIONING

Two air conditioning systems are available: the large
capacity (central HVAC system) or the small
capacity A/C (small HVAC system). Vehicles
equipped with the large capacity HVAC system
benefit from a combination heating and cooling
system
conditioned and filtered air for all climatic conditions.
Fresh air is drawn into the system from the left
(driver's) side of the vehicle. Return air is taken from
the middle of the vehicle. The driver's heater and
defogger are controlled separately from the central
unit. An air mixture selector enables air to be drawn
into the system from outside the vehicle or
recirculated. Driver's air provides cooling for the
driver's area only, maximizing available baggage
space for other uses. The small capacity HVAC
system enables cooling the driver's area only.
CENTRAL HVAC SYSTEM
Air conditioning
capacity
Refrigerant type
Heating capacity
Air flow
SMALL HVAC SYSTEM
Air conditioning
capacity
Refrigerant type
Air flow
Refrigerant nominal
charge
COMPRESSOR (central HVAC sys-
tem)
Number of cylinders
Operating speed
PA-1638 Owner's Manual X3-45 VIP
Exhaust pipe with Insulation and a flexible
l
section.
Exhaust to rear rooftop left hand corner.
l
Diesel exhaust fluid (DEF) tank (60 liters) and
l
injection system.
that
provides
adequate
9 tons
134A
150 000 Btu/h
2 600 cfm (73,6 m
2 tons
134A
450 cfm (12,7 m
6 lbs
4
500 to 3500 rpm
capacity
of
3
/min)
3
/min)

Advertisement