SLIDE-OUT TROUBLESHOOTING

Error condition or missing operation
condition
When an error condition or a missing operation
condition is present on a slide-out, the green
indicator light on its respective handheld control
starts blinking upon releasing of the IN/OUT
rocker switch.
Turning the ignition OFF and ON again, will stop
the blinking and reset the fault. If the error
condition or a missing operation condition is still
present, the blinking will start again the next time
that the slide-out is operated. So, to get a fault
diagnostic, use the Driver Information Display
(DID) right after operating the slide-out without
cycling the ignition switch.
Fault Diagnostics
To get more specific information about the error
condition or the missing operation condition,
request a diagnostic from the slide-out CECM
using the Driver Information Display (DID).
Check if there are active errors in the slide-out
electrical system. With the Diagnostics menu,
highlight Fault Diagnostics and then highlight
Electrical System to request a diagnostic of the
TROUBLESHOOTING – OPERATING CONDITIONS, CONTROL & MECHANICAL COMPONENTS
PROBLEM
CAUSE
The slide-out
A.
Something is defective and may eventually
functions
create an issue if not repaired. The problem
normally but
may be:
the handheld
B.
Faulty limit sensor causing the slide-out to
control green
stop in overcurrent;
indicator light
blinks
C. CAN
transmission
operational;
D. Vacuum pressure transducer disconnected or
damaged (vacuum is applied for a fixed time
of 7 seconds);
E.
Seal inflating valve solenoid open circuit (the
seal is not re-inflated and water can
penetrate in the vehicle);
F.
Security pin valve solenoid open circuit (the
security pin is not extended while vehicle is
riding).
network
problem
causing
inhibit
safety
to
electrical system from the MCM. Press the enter
key.
If applicable, the DID shows the device ID, the
fault messages or fault codes recorded. When
more than one fault is recorded, an arrow
pointing down appears on the right of the
display. Use the down arrow to see all the fault
messages.
Once the problem corrected, the DID still shows
the fault as being active. You have to leave the
Fault Diagnostics menu, wait approximately 20
to 30 seconds and then return to Fault
Diagnostics to request a new diagnostic of the
Electrical System from the MCM. The DID
should display the fault as being inactive.
CORRECTIVE ACTION
Using the Driver Information Display
(DID), check if there are active errors in
the vehicle electrical system. With the
Diagnostics
Diagnostics and then highlight Electrical
System to request a diagnostic of the
electrical system from the MCM.
the
be
non-
menu,
highlight
Fault