Procedure
1. Prepare a master virtual SVP image:
a. Create the virtual SVP using the procedure in
page 109)
b. Configure the SVP guest OS using the procedure in
OS (on page 112)
c. Install the SVP using the procedure in
page 92)
addition, do not register a DKC using the Storage Device List.
2. Turn off the master virtual SVP.
3. Clone the master virtual SVP, and then start the cloned virtual SVP.
4. Configure the Windows OS network information in the cloned virtual SVP.
5. Set the IP address for the SVP. This IP address is used to communicate with the
storage system.
6. Register a storage system using the Storage Device List.

Detecting SVP failures

SVP failures are detected and resolved using the following methods.
Failure detection method
Hi-Track Remote
Monitoring System
Hitachi Command Suite
(HCS)
Hitachi Storage Advisor
(HSA)
Chapter 7: Installing the SVP software on a VMware ESXi host
. You do not have to set up the network at this time.
.
. You do not have to configure the SVP IP address at this time. In
How a failure is detected
No report from the agent
during a 24-hour health
check
RMI connection error (not
alert)
Hardware alerts appear in
Alert tiles, along with drill-
down views for detailed
information.
Service Processor Technical Reference
Detecting SVP failures
Configuring the virtual SVP (on
Configuring the SVP guest
Completing the configuration (on
Action to be taken
Hi-Track detects SVP failure
-> SVP replacement. For
information about Hi-Track,
go to the Hi-Track website:
http://hitrack.hds.com/.
See the Hitachi Command
Suite Administrator Guide
(MK-90HC175).
See Hitachi Storage Advisor
User Guide (MK-94HSA004).