Initializing automatically allocated port numbers

Before you begin
Verify the client PC is already connected to the SVP through the Remote Desktop
Connection.
Stop the services of all the storage systems that have a Ready status in the Storage
Device List window, and then initialize them.
If storage systems are initialized without stopping the services, the storage system
port numbers get reallocated automatically. For more information, see
automatically allocated port numbers (on page 221)
Procedure
1. Log out of Device Manager - Storage Navigator.
2. In the Storage Device List window, stop the services of all the storage systems that
have a Ready status.
3. On the SVP, start a Windows command prompt as an Administrator.
4. Change the current directory to the directory where the tool exists and run the
following command: C:\Mapp\wk\Supervisor\MappIniSet
\MappPortManageInit.bat
5. At the confirmation message for reallocation, enter y and press Enter to continue
or enter n and press Enter to cancel the processing.
6. At the completion message, press any key to continue.
7. Perform the reallocation by running the following command: C:\Mapp\wk
\Supervisor\MappIniSet\MappPortManageRenum.bat_[Serial number]
(arbitrary)
If the [Serial number] is omitted, the command is performed for storage
systems running firmware version 83-03-01-xx/00 or later.
8. At the confirmation message for reallocation, type y and press Enter to continue or
type n and press Enter to cancel the processing.
9. At the completion message, press any key to continue.
10. Repeat steps 6 through 9 to reallocate the port numbers for all the registered
storage systems.
11. Close the command prompt.
Chapter 14: Changing and initializing SVP port numbers
Tip: C:\MAPP indicates the installation directory of the storage
management software and SVP software. If the installation directory is
not C:\Mapp, replace C:\Mapp with the appropriate installation
directory.
Tip: C:\MAPP indicates the installation directory of the storage
management software and SVP software. When the installation
directory, other than C:\Mapp is specified, replace C:\MAPP with the
specified installation directory.