Initializing automatically allocated port numbers
Before you begin
Verify the client PC is already connected to the SVP through the Remote Desktop
■
Connection.
Stop the services of all the storage systems that have a Ready status in the Storage
■
Device List window, and then initialize them.
If storage systems are initialized without stopping the services, the storage system
■
port numbers get reallocated automatically. For more information, see
automatically allocated port numbers (on page 221)
Procedure
1. Log out of Device Manager - Storage Navigator.
2. In the Storage Device List window, stop the services of all the storage systems that
have a Ready status.
3. On the SVP, start a Windows command prompt as an Administrator.
4. Change the current directory to the directory where the tool exists and run the
following command: C:\Mapp\wk\Supervisor\MappIniSet
\MappPortManageInit.bat
5. At the confirmation message for reallocation, enter y and press Enter to continue
or enter n and press Enter to cancel the processing.
6. At the completion message, press any key to continue.
7. Perform the reallocation by running the following command: C:\Mapp\wk
\Supervisor\MappIniSet\MappPortManageRenum.bat_[Serial number]
(arbitrary)
If the [Serial number] is omitted, the command is performed for storage
systems running firmware version 83-03-01-xx/00 or later.
8. At the confirmation message for reallocation, type y and press Enter to continue or
type n and press Enter to cancel the processing.
9. At the completion message, press any key to continue.
10. Repeat steps 6 through 9 to reallocate the port numbers for all the registered
storage systems.
11. Close the command prompt.
Chapter 14: Changing and initializing SVP port numbers
Tip: C:\MAPP indicates the installation directory of the storage
management software and SVP software. If the installation directory is
not C:\Mapp, replace C:\Mapp with the appropriate installation
directory.
Tip: C:\MAPP indicates the installation directory of the storage
management software and SVP software. When the installation
directory, other than C:\Mapp is specified, replace C:\MAPP with the
specified installation directory.
Service Processor Technical Reference
Initializing automatically allocated port numbers
.
Reallocating
222