18. Click OK.
19. Wait for the firmware upgrade to complete, and then verify the firmware update
status in the Firmware (Storage System) column of the Environmental Settings
window. Wait for the firmware update to complete. The following table lists the
status conditions.
Status
(Select Update)
In progress
Completed
Failed
Communication Timeout
(Not Update)
Note:
1. When NAS Modules are not installed, the installation time is approximately 3.5
hours. When NAS modules are installed, the installation time is approximately 9
hours.
20. When the firmware upgrade completes, click Close.
Chapter 16: Deleting and registering the storage system
Service Processor Technical Reference
Registering the storage system on the SVP
Description
Click Update to display the Update
Firmware window.
The Update Firmware window started
and the firmware upgrade is not
complete. This status appears even if
the firmware upgrade is canceled.
Firmware upgrade is complete.
Firmware upgrade failed. Click Update
to display the Update Firmware
window, and review the error details.
1
The time
required to complete the
firmware upgrade cannot be confirmed.
Verify the state in the Update
Firmware window.
Not selected as a firmware upgrade
target.
246