18
|
Piping installation
18 Piping installation
In this chapter
18.1 Preparing refrigerant piping
18.1.1 Refrigerant piping requirements
Installer and user reference guide
68
18.1
Preparing refrigerant piping ...................................................................................................................................................
18.1.1
Refrigerant piping requirements ...........................................................................................................................
18.1.2
Refrigerant piping insulation..................................................................................................................................
18.1.3
To select the piping size .........................................................................................................................................
18.1.4
18.1.5
About the piping length .........................................................................................................................................
18.1.6
Piping length: VRV DX only.....................................................................................................................................
18.1.7
18.1.8
18.1.9
18.2
Connecting the refrigerant piping..........................................................................................................................................
18.2.1
18.2.2
18.2.3
18.2.4
To route the refrigerant piping ..............................................................................................................................
18.2.5
18.2.6
18.2.7
18.2.8
18.2.9
To braze the pipe end ............................................................................................................................................
18.2.11 To remove the spun pipes .....................................................................................................................................
18.3
Checking the refrigerant piping..............................................................................................................................................
18.3.1
18.3.2
18.3.3
18.3.4
To perform a leak test............................................................................................................................................
18.3.5
To perform vacuum drying ....................................................................................................................................
18.3.6
18.4
Charging refrigerant ...............................................................................................................................................................
18.4.1
18.4.2
About charging refrigerant ....................................................................................................................................
18.4.3
18.4.4
18.4.5
To charge refrigerant .............................................................................................................................................
18.4.6
18.4.7
18.4.8
NOTICE
The refrigerant R410A requires strict cautions for keeping the system clean, dry and
tight.
▪
Clean and dry: foreign materials (including mineral oils or moisture) should be
prevented from getting mixed into the system.
▪
Tight: R410A does not contain any chlorine, does not destroy the ozone layer,
and does not reduce earth's protection against harmful ultraviolet radiation.
R410A can contribute to the greenhouse effect if it is released. Therefore pay
special attention to check the tightness of the installation.
68
68
69
69
72
73
74
77
78
79
81
81
81
82
82
83
84
84
85
86
86
89
90
90
91
92
92
93
93
94
94
95
95
97
98
RXMLQ8 + RXYLQ10~14T7Y1B*
VRV IV system air conditioner
4P543427-1A - 2020.10
Need help?
Do you have a question about the VRV IV and is the answer not in the manual?