RXMLQ8 + RXYLQ10~14T7Y1B*
VRV IV system air conditioner
4P543427-1A – 2020.10
3
WARNING
NEVER remove the spun piping by brazing.
Any gas or oil remaining inside the stop valve may blow off the spun piping.
WARNING
ONLY use R410A as refrigerant. Other substances may cause explosions and
accidents.
R410A contains fluorinated greenhouse gases. Its global warming potential (GWP)
value is 2087.5. Do NOT vent these gases into the atmosphere.
When charging refrigerant, ALWAYS use protective gloves and safety glasses.
CAUTION
Do NOT push or place redundant cable length in the unit.
WARNING
If the power supply has a missing or wrong N-phase, equipment might break
down.
Establish proper earthing. Do NOT earth the unit to a utility pipe, surge absorber,
or telephone earth. Incomplete earthing may cause electrical shock.
Install the required fuses or circuit breakers.
Secure the electrical wiring with cable ties so that the cables do NOT come in
contact with sharp edges or piping, particularly on the high-pressure side.
Do NOT use taped wires, stranded conductor wires, extension cords, or
connections from a star system. They can cause overheating, electrical shock or
fire.
Do NOT install a phase advancing capacitor, because this unit is equipped with an
inverter. A phase advancing capacitor will reduce performance and may cause
accidents.
WARNING
All wiring MUST be performed by an authorised electrician and MUST comply
with the applicable legislation.
Make electrical connections to the fixed wiring.
All components procured on-site and all electrical construction MUST comply
with the applicable legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
Specific installer safety instructions
|
Installer and user reference guide
15

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VRV IV and is the answer not in the manual?

Questions and answers

MUHAMMAD SHAMSUDDEEN
March 21, 2025

Hi, kindly assist me with resolving the problem of the VRV IV series. It pops up from the remote control, and after checking the master and the slaves, both cannot identify their ID number. though the last error was e2. Someone messed up with the wiring, perhaps the communication cable. If we can see what cable goes to the first unit from the master, we have 16 units attached.

1 comments:
Mr. Anderson
March 21, 2025

The troubleshooting steps for a Daikin VRV IV series system with an E2 error and communication issues between the master and slave units are:

1. Check Q1/Q2 Wiring: Inspect the wiring connections between the master and slave units at the Q1/Q2 terminals. Faulty or incorrect wiring can cause communication failures.

2. Verify Indoor-Outdoor Wiring: Ensure that the wiring between the indoor and outdoor units is correctly connected at the Q1/Q2 and F1/F2 terminals. Incorrect connections can lead to system malfunctions.

3. Check System Test Run: If the system test run was not executed or ended abnormally, perform the test run again to identify potential issues.

4. Confirm Indoor Unit Configuration: Ensure that the number of indoor units connected to the F1/F2 line does not exceed the system's capacity. Too many units can cause communication failures.

5. Inspect System Compatibility: Verify that the indoor units connected are compatible with the system (e.g., R410A, R407C, Hydrobox). Mixing incompatible units may cause communication issues.

6. Examine Outdoor Unit Wiring: Ensure that the interconnecting wiring between outdoor units in the same piping system is connected to the Q1/Q2 (Out Multi) terminals. Incorrect wiring to the F1/F2 terminals can cause system malfunctions.

Following these steps should help diagnose and resolve communication issues in the VRV IV system.

This answer is automatically generated