4
|
User safety instructions
4 User safety instructions
In this chapter
4.1 General
Installer and user reference guide
18
Always observe the following safety instructions and regulations.
4.1
General....................................................................................................................................................................................
4.2
Instructions for safe operation...............................................................................................................................................
WARNING
If you are NOT sure how to operate the unit, contact your
installer.
WARNING
Children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of
experience and knowledge can only use this appliance if
they have been given supervision or instruction concerning
the use of the appliance by a person responsible for their
safety.
Children MUST NOT play with the appliance.
Cleaning and user maintenance MUST NOT be carried out
by children without supervision.
WARNING
To prevent electrical shocks or fire:
▪
Do NOT rinse the unit.
▪
Do NOT operate the unit with wet hands.
▪
Do NOT place any objects containing water on the unit.
CAUTION
▪
Do NOT place any objects or equipment on top of the
unit.
▪
Do NOT sit, climb or stand on the unit.
18
19
RXMLQ8 + RXYLQ10~14T7Y1B*
VRV IV system air conditioner
4P543427-1A – 2020.10
Need help?
Do you have a question about the VRV IV and is the answer not in the manual?
Questions and answers
Hi, kindly assist me with resolving the problem of the VRV IV series. It pops up from the remote control, and after checking the master and the slaves, both cannot identify their ID number. though the last error was e2. Someone messed up with the wiring, perhaps the communication cable. If we can see what cable goes to the first unit from the master, we have 16 units attached.
The troubleshooting steps for a Daikin VRV IV series system with an E2 error and communication issues between the master and slave units are:
1. Check Q1/Q2 Wiring: Inspect the wiring connections between the master and slave units at the Q1/Q2 terminals. Faulty or incorrect wiring can cause communication failures.
2. Verify Indoor-Outdoor Wiring: Ensure that the wiring between the indoor and outdoor units is correctly connected at the Q1/Q2 and F1/F2 terminals. Incorrect connections can lead to system malfunctions.
3. Check System Test Run: If the system test run was not executed or ended abnormally, perform the test run again to identify potential issues.
4. Confirm Indoor Unit Configuration: Ensure that the number of indoor units connected to the F1/F2 line does not exceed the system's capacity. Too many units can cause communication failures.
5. Inspect System Compatibility: Verify that the indoor units connected are compatible with the system (e.g., R410A, R407C, Hydrobox). Mixing incompatible units may cause communication issues.
6. Examine Outdoor Unit Wiring: Ensure that the interconnecting wiring between outdoor units in the same piping system is connected to the Q1/Q2 (Out Multi) terminals. Incorrect wiring to the F1/F2 terminals can cause system malfunctions.
Following these steps should help diagnose and resolve communication issues in the VRV IV system.
This answer is automatically generated