(3). Connect the Red Charger Jack to positive (+) battery terminal and the
Black Charger Jack to negative (-).
(4). Turn the ECO Switch to the "OFF" position.
(5). Start the engine to charge the battery.
(6). Charging time will vary with battery size and condition. The DC Circuit
Breaker 6 does not prevent over-charging a battery.
The 12V DC Receptacle should ONLY be used for charging 12V
automotive type batteries. The 12V DC output is unregulated and
will damage other 12V DC products.
When using the 12V DC output, turn the ECO Switch to the "OFF"
position.
NEVER reverse the polarity when connecting the battery terminals to
the charging jack. Severe damage may occur to the generator and
battery.
Do not start the vehicle while the battery charging cable is connected
and the generator is running. The vehicle or the generator may be
damaged.
An overloaded DC circuit or a wiring problem will trip the DC Circuit
Breaker 6 (PUSH button extends out). If this happens, wait a few
minutes before pushing in the DC Circuit Breaker 6 to resume
operation. If the DC Circuit Breaker 6 continues to go OFF,
discontinue charging and contact your authorized generator dealer.

7.2 DISCONNECTING THE BATTERY CHARGING CABLE:

(1). Turn the Engine Switch to "OFF" position to stop the engine.
(2). Disconnect the Black Charger Jack of the Battery Charging Cable from the
negative (-) battery terminal.
(3). Disconnect the Red Charger Jack of the Battery Charging Cable from the
<<29>>
positive (+) battery terminal.
(4). Disconnect the Battery Charging Cable from the 12V DC Receptacle of the
generator.
(5). Connect the vehicle battery ground cable to the negative (-) battery