Advertisement

Quick Links

EZG6000/EZG6000UK
U S E R G U I D E
O R I G I N A L I N S T R U C T I O N S
1

Advertisement

Table of Contents
loading

Summary of Contents for Energizer EZG6000

  • Page 1 EZG6000/EZG6000UK U S E R G U I D E O R I G I N A L I N S T R U C T I O N S...
  • Page 2 Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by Builder SAS. All other brand names are trademarks of their respective owners. Neither Builder SAS nor Energizer Brands, LLC is affiliated with the respective owners of their trademarks.
  • Page 3 Thanks for choosing the EZG Series! You're excited to power up, so we'll keep this brief. Let's get started!
  • Page 4: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTION 2. COMPONENT IDENTIFICATION 3. CONTROLS 1) Engine Switch 2) Recoil Starter 3) Fuel Valve 4) Choke 5) Circuit Breaker 6) Ground Terminal 7) Oil Alert System 4. GENERATOR USE 1) Connections to a Building's Electrical System 2) Ground System 3) AC Applications 4) AC Operation...
  • Page 5: Safety Instruction

    1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
  • Page 6  Run the generator in respect of the power indicated in the user’s manual. Do not run the generator with an overload or at excessive speed.  The silencer of the generator becomes extremely hot when the motor runs or even for a time after it has stopped.
  • Page 7  Some parts of the internal combustion engine are hot and may cause burns. Pay attention to the warnings on the generating set.  Engine exhaust gases are toxic. Do not operate the generating set in unventilated rooms. When installed in ventilated rooms, additional requirements for fire and explosion protection shall be observed.
  • Page 8  Never fill the fuel tank while smoking or near a naked flame.  Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling with fuel.  Keep the fuel in an appropriate recipient and sheltered from any sources of fire. ...
  • Page 9 applicable laws and norms in the field of electricity. Incorrect connections will cause leakage of the current from the generator into the lines of the public electricity company. Such leakage could electrocute the workers of the public electricity company working on the network or other persons in contact with the line during a power cut.
  • Page 10: Component Identification

    Add engine oil. Guaranteed sound power level No naked flames Ground connection It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death. This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful to health of body No naked fire near the machine!
  • Page 11: Controls

    3. CONTROLS 1) Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine. Key can be removed/inserted. ON: To run the engine after starting. START: To start the engine by turning the starter motor. With Electric Starter Without Electric Starter...
  • Page 12 Return the key to the ON position once the engine has started. Do not use the starter for more than 5 seconds at a time. If the engine fails to start, release the switch and wait 10 seconds before operating the starter again. 2) Recoil Starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly.
  • Page 13: Generator Use

    5) Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again.
  • Page 14 Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. WARNING Improper connections to a building's electrical system, can allow electrical current from the generator to feedback into the utility lines.
  • Page 15 Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately.
  • Page 16 DC Circuit Protector (or DC Fuse) The DC circuit protector(or DC Fuse) automatically shuts off the DC battery charging circuit when the DC circuit is overloaded, when there is a problem with the battery, or the connections between the battery and the generator are improper. The indicator inside the DC circuit protector button will pop out to show that the DC circuit protector has switched off.
  • Page 17: Pre-Operation Check

    An overloaded DC circuit, excessive current draw by the battery, or a wiring problem will trip the DC circuit protector (PUSH button extends out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation. If the circuit protector continues to go OFF, discontinue charging and see your authorized generator dealer.
  • Page 18 Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage the engine and are not recommended. Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped.
  • Page 19 WARNING • Gasoline is extremely flammable and is explosive under certain conditions. • Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored. •...
  • Page 20: Starting/Stopping The Engine

    Some gasoline are blended with alcohol or an ether compound to increase the octane. These gasoline are collectively referred to as oxygenated fuels. Some areas of the United States use oxygenated fuels to help meet clean air standards. If you use an oxygenated fuel, be sure its pump octane rating is 86 or higher.
  • Page 21: Maintenance

    Turn the engine switch to the ON position. Pull the starter grip until compression is felt, then pull briskly. NOTICE Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter or housing. •...
  • Page 22 Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform the service and inspection at the intervals shown in the Maintenance schedule below. 1) MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD Performed at Each use First month Every 3 Every 6 Every year...
  • Page 23 NOTE: Diagrams may vary according to the types. 3) Engine oil change Drain the oil while the engine is warm to assure complete and rapid draining 1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil 2.
  • Page 24 WARNING Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Use only soapy water or nonflammable solvent. NOTICE Never run the generator without the air cleaner. Rapid engine wear will result. 1) Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2) Wash the element in a solution of household detergent and warm water, then rinse thoroughly;...
  • Page 25 5) Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1) Turn the fuel valve to the OFF position.
  • Page 26: Transporting And Storage

    5) Measure the plug gap with a feeler gauge. Correct as necessary by carefully bending the side electrode. The gap should be: 0.70-0.80 mm (0.028-0.031 in). 6) Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading.
  • Page 27 Before storing the unit for an extended period: • Be sure the storage area is free of excessive humidity and dust. • Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required.
  • Page 28: Troubleshooting

    4) Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion. Align the notch on the starter pulley with the hole at the top of recoil starter.
  • Page 29 No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or Take the generator to an DEFECTS equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
  • Page 30 10. CIRCUIT DIAGRAM...
  • Page 32: Specifications

    11. SPECIFICATIONS Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 389cc Rated speed 3600/min Igniting system Transistor magneto Starting system Recoil Fuel Volume (L) 25 L Continuous operation time (h) Min. Fuel consumption (g/kW.h) 360 g/kW.h Lube. Oil capacity (L) 1.1 L Sound pressure level: L 73.46 dB(A), K = 2.0dB(A)
  • Page 33 WARRANTY The manufacturer warrants the product against defects in materials and workmanship for a period of 2 years from the date of purchase to the original purchaser. The guarantee applies when the product is used as a home tool. The warranty does not extend for failures due to normal wear and tear. The manufacturer agrees to replace the spare parts that are classified as defective by a designated distributor.
  • Page 34 In order to get help about your Generator, we invite you to go through this link to call us by phone +33 (0)8.20.20.22.68: https://services.swap-europe.com/contact You need to create a "ticket" via their platform.  Login or create your account  Put your tool reference ...
  • Page 35: Ec Declaration

    ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator Model: EZG6000/EZG6000UK Serial number: Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it: Also complies with the following European directives:...

This manual is also suitable for:

Ezg seriesEzg6000uk

Table of Contents