  • Page 1 ORIGINAL INSTRUCTIONS PETROL INVERTER GENERATOR EZG1600i-A-UK USER GUIDE CAUTION Read the instructions before using the machine...
  • Page 2 ©2020 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by Builder SAS..
  • Page 3 Let’s get started. You’re excited to power up, so we’ll keep this brief!
  • Page 4: Table Of Contents

    CONTENTS 1. Safety Instruction···········································································5 2. Quick Start ····················································································10 3. Safety Label Location···································································12 4. Parts Identification········································································13 5. Check before Operation·······························································14 6. Start the Engine············································································17 7. Operating the Generator······························································19 8. Shut off the Generator·································································25 9. Maintenance ················································································26 10.Transportation/Storage······························································31 11.Troubleshooting·········································································32 12. Specifications············································································35 13. CE declaration of conformity……………………….……………36 14.
  • Page 5: Safety Instruction

    1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
  • Page 6 has stopped. Do not touch it as it will burn you.  Do not transport or move the generator until it has cooled down.  Perform periodic maintenance and resolve problems that appear immediately. Do not run the generator before correcting any fault detected. ...
  • Page 7  Due to high mechanical stresses, only tough rubber-sheathed flexible cable (in accordance with IEC 60245-4) or the equivalent should be used.  The user shall conform to regulations of electrical safety applicable to the place where the generating sets are used. ...
  • Page 8  Do not run the generator under rain or snow.  Do not run the generator near water.  Connect the generator to earth. Use a sufficiently thick conductor for the earth wire.  Do not operate the generator in parallel with another generator. ...
  • Page 9 Conforms to relevant safety standards Do not dispose of old appliances with domestic rubbish . Guaranteed sound power level Ground connection Fill in engine oil It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death. This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful to health of body...
  • Page 10: Quick Start

    2. Quick Start WARNING Only use outdoors . The generator emits carbon monoxide, a toxic colorless and odorless gas  that can cause death or serious injury. Ensure that the generator is placed horizontally.  Never work in the rain, snow or other humid environment. ...
  • Page 11 Forewords Thank you for Choosing our generator. This manual includes the operation and maintenance of Model EZG1600i-A-UK series inverter generator. All contents of this manual are consistent with the latest products (when this manual is printed). Our company reserves the right to make changes without notice and without any liability.
  • Page 12: Safety Label Location

    As long as following the instructions in this manual, the generators are safe and reliable. Be sure to read and understand the instructions before use, otherwise the wrong operation will result in personal injury or equipment damage. Generator specification: Model EZG1600i-A-UK Rated voltage(V) Rated frequency(HZ) Rated current(A)...
  • Page 13: Parts Identification

    4. Parts Identification The configurations of control panel might be different. Fuel Cap Handle Control Panel Fuel tank Exhaust port Feet...
  • Page 14: Check Before Operation

    Engine Oil filler Air filter Oil Switch Choke Cable Control Panel Overload light AC SOCKET Output indicate Fuel alert indicate DC protect Starting swithing DC output ECO switch Earth stud 5.Check before Operation BE CAUTIOUS  Be sure to check whether the generator is placed horizontally, and the engine is off. Check the Oil Level BE CAUTIOUS ...
  • Page 15 SEA viscosity grade as follows: Loosen the screw on the side maintenance cover to remove the cover. Remove the oil dipstick, wipe the dipstick with a clean cloth, insert it into the oil port without tightening the dipstick to check the oil level. If the oil level is below the bottom of the dipstick, add the recommended oil.
  • Page 16 Oil cap WARNING Under certain conditions gasoline is extremely flammable and explosive.  Please refuel in the ventilated place and turn off the engine when refueling. Generator refueling area and  gasoline storage area is strictly prohibited smoking and lighting fires. Never add fuel when the generator is running.
  • Page 17: Start The Engine

    BE CAUTIOUS  Never run the engine without a filter, or dirt will enter the engine through the carburetor and cause rapid wear of the engine. 6.Start the Engine Recoil Start Disconnect the load from the socket before starting the generator. 1.
  • Page 18 4. Pull the starter handle until you feel resistance, then quickly pull the handle as the direction shown above to start the generator. BE CAUTIOUS  Never allow the starting handle to rebound. Slowly put it back.  When pulling the cable, hold the generator tightly to prevent the generator from overturning.
  • Page 19: Operating The Generator

    Working at high altitudes In high altitude areas, the air-fuel mix in a standard carburetor is relatively thick, so the engine operating performance will reduce, while the fuel consumption increases. At this point you can adjust the main jet on the carburetor (smaller), while adjusting the ratio-mixing screw, then you can change the performance of the engine in high altitude areas.
  • Page 20 NOTICE  When using AC power, you can use DC power at the same time. Please pay attention to the sum of the power of AC and DC. It cannot exceed the rated power of the generator. Use of AC Power Connect the ground bolt.
  • Page 21 If the generator is overloading or the connected device is internally faulty, the power indicator (green) will go off and the overload indicator (red) will light up and there is no power output. The generator will still keep running until you turn the start switch to “OFF”...
  • Page 22 When using the generator with a pure inductive load, the pure inductive load cannot exceed the rated power of the generator. The power can only run 40% to 75% of rated power on pure inductive load. Model HG1600i-A Rated Power (W) 1000 Frequency(Hz)...
  • Page 23 1. Connect the charging cable to the generator DC socket and connect it to the battery terminal Charging Cable WARNING  Connect the charging cable to the battery first, and then connect it to the generator. Disassembly must start from the generator side, which prevents sparks start beside the battery. ...
  • Page 24 DC protector When using AC power, you can have use DC output. The DC circuit overload may cause DC protection. And the switch should be reset. DC protector Rated Power Output Conditions of the Generator The oil alarm system is designed to prevent damage to the engine due to insufficient oil. The oil alarm system automatically shuts down the engine before the oil in the crankcase drops to the safety line (although the start switch remains in the "on"...
  • Page 25: Shut Off The Generator

    8.Shut off the generator If you need to shut down the engine urgently, turn the key to “stop” position. For Electric Start and Remote Start model, you can turn the power switch to “OFF” position. For Remote Start model, you can also press the red “STOP”...
  • Page 26: Maintenance

    9.Maintenance Maintenance and adjustment schedules are developed to keep the generator in the best working condition. WARNING  Turn off the engine before any maintenances. If the engine must be operated during maintenance, be sure to operate it in a ventilated area because the exhaust contains toxic carbon monoxide. NOTICE ...
  • Page 27 Oil Change When the engine is warm, you can quickly and completely discharge the oil. BE CAUTIOUS  Make sure that the engine switch and the fuel switch are off before draining the oil. a. Loosen the oil drain screw, drain the oil. b.
  • Page 28 BE CAUTIOUS  In order to comply with environmental requirements, we recommend that collect the waste oil into a sealed container, send to the repair station or recycling center near your location. Do not spill the oil on the ground or garbage. Maintenance of Air Filter The dirty air filter will block the air into the carburetor.
  • Page 29 Maintenance of Spark Plug Use recommended spark plug ( E7RTC): In order to ensure the best operation of the engine, the spark plug clearance must be appropriate. Spark plug cannot have coke. 1) Remove the top maintenance cover screws and remove the top maintenance cover plate. 2) Pull the anode cap out.
  • Page 30 4) If the insulator has been ruptured, it must be scrapped. If you want to use the spark plug again, use a brush to clean the spark plug. 5) Measure the spark plug clearance with a feeler gauge, and the spark plug clearance should be 0.6-0.7mm (0.024-0.028 in) 6) Install the spark plug carefully.
  • Page 31: Transportation/Storage

    Fireproof Screws 10.Transportation/Storage To prevent fuel leakage during transport or temporary storage, turn off the oil switch and place the generator in a location where no fuel leaks. WARNING When transporting the generator:  Do not fill too much fuel into fuel tank. (There should be no fuel in the filler). ...
  • Page 32: Troubleshooting

    2) Exhaust oil. Remove the spark plug, pour a tablespoon of clean oil into the cylinder, pull the start handle a few times to scatter the oil, and then install the spark plug back. Pull the handle slowly until it feels pressure. At this moment, the piston is rising to the top of its compression stroke and the exhaust valve is closed.
  • Page 33 NOTICE  If the generator cannot be started for the first time when the oil is added, or the oil is changed, the oil alarm indicator flashes when pulling the start handle, at this time, the generator should be shaken back and forth to ensure that the float of the oil alarm floats. If the generator still does not start, please follow the troubleshooting instruction above.
  • Page 34 No power in DC socket Is DC protector ON? Reset the DC protector Return the generator to an authorized dealer for further assistant. Underpowered Underpowered Dirty Clean or replace the air filter Check the air filter Replace the gasoline Check the quality of gasoline Return the generator to an authorized dealer for further assistant.
  • Page 35: Specifications

    12.Specifications Size and Weight EZG1600i-A-UK Model L x W x H (mm) 310*310*380 Net weight (kg) 15.5kg Engine Model XG154F Type 4-Stroke, 1-Cylinder, OHV Displacement 89cm Compression Ratio Engine Speed 3600rpm Cooling System Forced Air-Cooled Ignition System Oil Capacity 0.4 L Fuel Tank Capacity 4.5 L...
  • Page 36: Ce Declaration Of Conformity

    : +33 (0)5.34.502.503 States that the designated below machine: Product: Petrol Inverter generator Model: EZG1600i-A-UK Serial number: 20201242542-20201242691 is in confirmity with the essential requirements and other relavant provisions of the applicable European Directives,based on the application of European harmonized standerds.Any unauthorized modification of the apparatus voids this declaration.
  • Page 37: Warranty

    14. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
  • Page 38: Product Failure

    15. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 39: Warranty Exclusions

    16. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...