Context
l Both ends of an idle copper cable must be covered by an ESD cap.
l Do not bend copper cables over their minimum bend radius. Doing so may damage wires
l Connectors of copper cables must be clean to ensure normal communication. If a
l Ensure that the bend radius of the copper cables or optical fibers is greater than the
Tools and Accessories
l
l
l
l
l
Procedure
Step 1 Determine the number and type of ports to be connected and plan the cabling routes.
Step 2 Obtain the desired quantity and lengths of copper cables.
Step 3 Wear an ESD wrist strap or ESD gloves. When wearing an ESD wrist strap, ensure that it is in
close contact with your wrist and grounded properly.
Step 4 Attach temporary labels to both ends of each copper cable and number them corresponding to
port numbers. For details, see
Step 5 Connect the copper cables to ports on the switch, matching the numbers on the copper cables
to those on the ports. To connect them, align the copper cable connector with the port and
insert the connector. When you hear a click, the copper cable is securely connected. See
Figure
After connecting copper cables, verify that they are all correctly connected.
Issue 13 (2017-11-20)
NOTICE
in the cables.
connector is contaminated, clean it with cleaning fabric.
minimum bend rand required. For specific bend radiuses of various cables, see "Cables" in
the Hardware Description of the product.
ESD wrist strap or ESD gloves
Cable tie gun
Cable ties
Marker
Copper cable labels
7-5.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13.5.4 Engineering Labels for User
7 Connecting a Switch
Cables.