Chapter 13
Commands

13.1 List of Commands

Command
COMMunicate Group
:COMMunicate?
:COMMunicate:HEADer
:COMMunicate:LOCKout
:COMMunicate:REMote
:COMMunicate:VERBose
:COMMunicate:WAIT
:COMMunicate:WAIT?
DEViation Group
:DEViation?
:DEViation:PRESet
:DEViation:VALue
DIVider Group
:DIVider?
:DIVider:DENominator
:DIVider:NUMerator
OUTPut Group
:OUTPut[:STATe]
:OUTPut:POLarity[:AUTO]
:OUTPut:POLarity:MAXimum
:OUTPut:POLarity:MINimum
SOURce Group
:SOURce?
:SOURce:FUNCtion
:SOURce:LEVel[:AUTO]
:SOURce:LEVel:MAXimum
:SOURce:LEVel:MINimum
:SOURce:RANGe
:SOURce:READ? [DUAL]
:SOURce:RJC?
:SOURce:RJC:MODE
:SOURce:RJC:STATe?
:SOURce:RJC:TEMPerature?
:SOURce:RJC:TEMPerature:AUTO
:SOURce:RJC:TEMPerature:EXTern
al?
:SOURce:RJC:TEMPerature:INTern
al?
:SOURce:RJC:TEMPerature:MANual
:SOURce:RJC:RESister?
:SOURce:RTD?
:SOURce:RTD:DEFine
:SOURce:RTD:DELete
:SOURce:RTD:SETTing?
IM 2560A-01EN
Function
Queries all communication settings.
Sets or queries whether headers are attached to query responses.
Sets/clears local lockout.
Sets or queries whether the 2560A is in remote or local mode. On is remote
mode.
Sets or queries whether the response to a query is returned fully spelled out
or in its abbreviated form.
Waits for a specified extended event to occur.
Creates the response that is returned when a specified extended event
occurs.
Queries all deviation settings.
Sets or queries the preset value.
Sets or queries the deviation.
Queries all output divider settings.
Sets or queries the denominator m of the output divider.
Sets or queries the numerator n of the output divider.
Sets or queries the output's on/off state.
Sets or queries the polarity of the main setting for main setting (MAX) or
main setting (MIN), whichever is selected.
Sets or queries the polarity of main setting (MAX).
Sets or queries the polarity of main setting (MIN).
Queries all source settings.
Sets or queries the source function.
Sets or queries the main setting for main setting (MAX) or main setting (MIN),
whichever is selected.
Sets or queries the main setting (MAX).
Sets or queries the main setting (MIN).
Sets or queries the voltage, current, or resistance range.
Queries the output value.
Queries all reference junction compensation settings.
Sets or queries the reference junction compensation mode.
Queries the reference junction compensation operating state.
Queries the reference junction compensation temperature.
Sets or queries the reference junction compensation temperature.
Queries the external reference junction temperature.
Queries the 2560A's internal reference junction (2560A low voltage-current
output terminal) temperature.
Sets or queries the temperature for when the reference junction
compensation mode is set to manual input.
Queries the resistance of the RJ sensor to be used for the external reference
junction for 0°C.
Queries all user-defined RTD settings.
Sets a user-defined RTD.
Deletes user-defined RTDs.
Queries all temperature range settings that are user-defined for the RTD.
1
2
Page
3
13-4
13-4
13-4
13-4
4
13-4
5
13-4
13-4
6
13-5
13-5
7
13-5
13-6
8
13-6
13-6
9
13-7
13-7
10
13-7
13-7
11
13-8
13-8
13-8
12
13-9
13-9
13
13-10
13-10
13-11
13-11
14
13-11
13-12
13-12
13-12
15
13-12
16
13-12
13-12
13-12
App
13-12
13-13
13-13
Index
13-1

Advertisement

Table of Contents
loading

Table of Contents